Electrical activity of the diaphragm in a small cohort of term neonates.

نویسندگان

  • Howard M Stein
  • Jacqueline Wilmoth
  • Jill Burton
چکیده

BACKGROUND Electrical activity of the diaphragm (E(di)) has been proposed as a parameter to evaluate respiratory function. Normative values of electrical activity of the diaphragm in full-term neonates are not known. This is a small case series to establish preliminary values of E(di) in term neonates and to determine how these values vary while awake and asleep and during feeding states. METHODS Three term neonates in room air and nippling feeds at the time of the study were observed for 4 hours. E(di) was measured by electrodes within a nasogastric tube positioned at the level of the diaphragm. Respiratory rate and heart rate were also recorded. Time while awake and asleep were noted. Feeding states included feeding, 30 min pre-prandial, and 30 min post-prandial. Statistics were analysis of variance and t tests, with P < .05. RESULTS Mean E(di) peak was 11 ± 5 μV. Mean E(di) minimum was 3 ± 2 μV. E(di) peak and minimum were higher while awake. E(di) peak was lower post-prandial. Respiratory rate was higher post-prandial. CONCLUSIONS These are the first preliminary values for E(di) in neonates. Higher E(di) peak while awake may reflect larger tidal volume to meet increased metabolic requirements when awake and active. Post-prandial lower E(di) peak and higher respiratory rate may indicate compensation for decreased tidal volume from increased intra-abdominal pressure. These data may be useful in identifying respiratory pathology in neonates and monitoring progression toward respiratory health.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simulation and Modeling of a High Sensitivity Micro-electro-mechanical Systems Capacitive Pressure Sensor with Small Size and Clamped Square Diaphragm

This paper proposes a Micro-electro-mechanical (MEMS) capacitive pressure sensor that relies on the movable electrode displaced like a flat plate equal to the maximum center deflection of diaphragm. The diaphragm, movable electrode and mechanical coupling are made of polysilicon, gold and Si3N4, respectively. The fixed electrode is gold and the substrate is Pyrex glass. This proposed method inc...

متن کامل

New Design of Mems piezoresistive pressure sensor

The electromechanical analysis of a piezoresistive pressure microsensor with a square-shaped diaphragm for low-pressure biomedical applications is presented. This analysis is developed through a novel model and a finite element method (FEM) model. A microsensor with a diaphragm 1000 „m length and with thickness=400 µm is studied. The electric response of this microsensor is obtained with applyi...

متن کامل

Analytical Analysis of Capacitive Pressure Sensor with Clamped Diaphragm (RESEARCH NOTE)

Abstract   In this paper analytical analysis of capacitive pressure sensor with clamped diaphragm is presented. Mechanical and electrical properties of the sensor are theoretically analyzed based on theory of thin plates with small deflection and the results are evaluated by use of finite element analysis. The central deflection and capacitance values under uniform external pressure are calcula...

متن کامل

Evaluation of the Predictive Value of Umbilical Cord Serum Bilirubin Level for the Development of Subsequent Hyperbilirubinemia in Term and Late-Preterm Neonates

Background: Considering the increasing rates of early hospital discharge and kernicterus in healthy full term newborns, timely identification of neonates at risk of severe hyperbilirubinemia is of great significance. The aim of this study was to investigate the predictive value of umbilical cord serum (UCS) bilirubin level for subsequent hyperbilirubinemia. Moreover, we compared the predictive ...

متن کامل

The Effect of Corrugations on Mechanical Sensitivity of Diaphragm for MEMS Capacitive Microphone

In this paper the effect of corrugated diaphragm on performance of MEMS microphone is described. The corrugated diaphragm is modeled in order to improve the sensitivity of micromachined silicon acoustic sensor. Analytical analyzes have been carried out to derive mathematic expressions for the mechanical sensitivity and displacement of corrugated diaphragm with residual stress. It is shown that ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 57 9  شماره 

صفحات  -

تاریخ انتشار 2012