An Implantable Left Atrial Pressure Sensor Lead Designed for Percutaneous Extraction Using Standard Techniques

نویسندگان

  • VICTOR PRETORIUS
  • ULRIKA BIRGERSDOTTER-GREEN
  • J THOMAS HEYWOOD
  • WERNER HAFELFINGER
  • DAN E GUTFINGER
  • NEAL L EIGLER
  • CHARLES J LOVE
  • WILLIAM T ABRAHAM
چکیده

BACKGROUND An implantable left atrial pressure (LAP) monitoring system for guiding the management of patients with advanced heart failure has the potential to require extraction, particularly in the setting of infection. The LAP sensor lead was designed to be suitable for ease of percutaneous extraction using standard techniques for extracting pacemaker and defibrillator leads. The clinical experience, to date, with percutaneous extraction of the LAP sensor lead is presented. METHODS A total of 82 patients underwent successful implantation of the LAP sensor lead using transseptal catheterization. Five patients of the 82 patients during a cumulative follow-up period of 267 patient-years (median of 2.9 years/patient) underwent percutaneous extraction using manual traction with a locking stylet and/or an excimer laser sheath to bore through adhesions. The distal fixation anchors of the LAP sensor lead are designed to fold forward during extraction so that the sensor module can easily separate from the interatrial septum. RESULTS Percutaneous extraction of the LAP sensor lead was accomplished successfully in all five patients with no embolic events, vascular tears, perforations, or other complications requiring surgical intervention. Manual traction alone was sufficient to detach the LAP sensor lead from the interatrial septum in all cases. Use of the excimer laser sheath was needed in selected cases to bore through scar tissue within the venous insertion site, but not within the heart. CONCLUSIONS The extraction of the LAP sensor lead was accomplished safely using standard techniques and equipment for percutaneously extracting pacemaker and defibrillator leads.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous Extraction of Transvenous Permanent Pacemaker/Defibrillator Leads

BACKGROUND Widespread use of cardiovascular implantable electronic devices has inevitably increased the need for lead revision/replacement. We report our experience in percutaneous extraction of transvenous permanent pacemaker/defibrillator leads. METHODS Thirty-six patients admitted to our centre from September 2005 through October 2012 for percutaneous lead extraction were included. Lead re...

متن کامل

Prevention of Sudden Death in Hypertrophic Cardiomyopathy

C ase presentation: A 14-yearold girl died suddenly and unexpectedly while exercising. Clinical and echocardiographic family screening identified hypertrophic cardiomyopathy (HCM) in her only sibling, an asymptomatic 17-year-old boy. In her brother, echocardiography showed extreme septal ventricular hypertrophy, 35 mm in thickness; left ventricular (LV) outflow obstruction was absent. Left atri...

متن کامل

Percutaneous Vacuum-Assisted Thrombectomy Device Used for Removal of Large Vegetations on Infected Pacemaker and Defibrillator Leads as an Adjunct to Lead Extraction.

This case series reports our early experience with a minimally invasive percutaneous method of safely removing large vegetations during lead extraction in septic cardiac implantable electronic devices (CIED). Debate exists concerning the management of vegetations involving these devices. Lead extraction is mandated for infections, but vegetations may embolize, causing complications. Surgical de...

متن کامل

Pacemaker laser lead extraction and reimplantation of dual-chamber implantable cardioverter defibrillator via Mustard baffle in complete transposition of great arteries.

We present a case of a complicated lead extraction and reimplantation of an implantable cardioverter defibrillator (ICD) in a young woman with complete transposition of great arteries (CTGA), a cyanotic congenital heart defect in which the aorta and the pulmonary trunk are transposed. The malformation results in two parallel circulations, whereby the left ventricle is attached to the pulmonary ...

متن کامل

Removal of Misplaced Left Ventricular Single Lead Pacemaker in a Patient Presenting with Recurrent Transient Ischemic Attacks

HINOJOS A, ILG K. Removal of Misplaced Left Ventricular Single Lead Pacemaker in a Patient Presenting with Recurrent Transient Ischemic Attacks. Spartan Med. Res. J. Vol. 2, No. 1, pp. 64-73, 2017. CONTEXT: Over 200,000 cardiac electronic implantable devices are annually placed in individuals living within the United States. Complications from this procedure can range up to 12%. Inadvertent lea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 36  شماره 

صفحات  -

تاریخ انتشار 2013