Light distribution in diffractive multifocal optics and its optimization.

نویسنده

  • Valdemar Portney
چکیده

PURPOSE To expand a geometrical model of diffraction efficiency and its interpretation to the multifocal optic and to introduce formulas for analysis of far and near light distribution and their application to multifocal intraocular lenses (IOLs) and to diffraction efficiency optimization. SETTING Medical device consulting firm, Newport Coast, California, USA. DESIGN Experimental study. METHOD Application of a geometrical model to the kinoform (single focus diffractive optical element) was expanded to a multifocal optic to produce analytical definitions of light split between far and near images and light loss to other diffraction orders. RESULTS The geometrical model gave a simple interpretation of light split in a diffractive multifocal IOL. An analytical definition of light split between far, near, and light loss was introduced as curve fitting formulas. Several examples of application to common multifocal diffractive IOLs were developed; for example, to light-split change with wavelength. The analytical definition of diffraction efficiency may assist in optimization of multifocal diffractive optics that minimize light loss. CONCLUSION Formulas for analysis of light split between different foci of multifocal diffractive IOLs are useful in interpreting diffraction efficiency dependence on physical characteristics, such as blaze heights of the diffractive grooves and wavelength of light, as well as for optimizing multifocal diffractive optics. FINANCIAL DISCLOSURE Disclosure is found in the footnotes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

اپتیک عدسی داخل چشمی چند کانونی تفرقی

The diffractive multifocal IOL provides simultaneous bifocal imaging by utilizing both diffractive and refractive optics. In both distant and near vision, there is a clear highly focused image on the retina. The second image is highly defocused, providing only faint background illumination. A small amount of the light goes to the higher orders of diffraction which are not perceptible by eyes. T...

متن کامل

Visual axial PSF of diffractive trifocal lenses.

The ophthalmic applications of a diffractive trifocal lens design with adjustable add powers and light distribution in the foci are investigated. Axial PSFs of the trifocal lenses are calculated and analyzed as a function of the design parameters and the eye pupil size. The optical performance in actual eyes is also simulated by including the measured ocular wave aberration functions of human e...

متن کامل

Multifocal IOLs with apodized diffractive central zone and refractive periphery: optical performance and clinical outcomes

The apodized diffractive multifocal intraocular lens is one of the intraocular lens types currently available for the correction of presbyopia. The design of apodized diffractive multifocal intraocular lenses improves on the visual outcomes obtained with the full optic diffractive and refractive intraocular lenses. In addition to the visual improvements, apodized diffractive multifocal intraocu...

متن کامل

Bilateral implantation of asymmetrical diffractive multifocal intraocular lenses.

OBJECTIVE To evaluate visual results after bilateral implantation of multifocal intraocular lenses (IOLs) with asymmetrical light distribution for the far and near focus. METHODS Twenty-nine patients underwent bilateral implantation of silicone-optic, foldable, diffractive IOLs in a prospective, 2-center, noncontrolled interventional study. Each patient had a distant-dominant multifocal IOL i...

متن کامل

Energy balance in apodized diffractive multifocal intraocular lenses

The energy distribution between the distance and near images formed in a model eye by three different apodized diffractive multifocal intraocular lenses (IOLs) is experimentally determined in an optical bench. The model eye has an artificial cornea with positive spherical aberration (SA) similar to human cornea. The level of SA upon the IOL, which is pupil size dependent, is controlled using a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 37 11  شماره 

صفحات  -

تاریخ انتشار 2011