Gore-Tex chin implants: a review of 324 cases.

نویسندگان

  • Michael Godin
  • Louis Costa
  • Thomas Romo
  • William Truswell
  • Tom Wang
  • Edwin Williams
چکیده

Augmentation of the chin is a long-standing and effective technique for facial enhancement. We have used preformed expanded polytetrafluoroethylene (Gore-Tex) implants for chin augmentation for several years. For this study, we collectively pooled data detailing our experiences with this material. From January 1, 1998, to March 30, 2001, a total of 324 Gore-Tex chin implants were placed. No resorption or visible movement of any implant occurred. Two (0.62%) of the 324 implants became infected and were ultimately removed. No other complications occurred. This complication rate compares favorably to other reports. Five implants (1.5%) were removed or changed in size due to patient requests. All remaining patients (97.8%) were satisfied with their result. We also describe technical points and procedure modifications that have helped us achieve beneficial results for our patients. Gore-Tex is a reliable implant material that helps the surgeon to achieve a high degree of patient satisfaction in chin augmentation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dual Plane Augmentation Genioplasty Using Gore-Tex Chin Implants

BACKGROUND The chin shape and position is important in determining the general shape of the face, and augmentation genioplasty is performed alone or in combination with other aesthetic procedures. However, augmentation genioplasty using osteotomy is an invasive and complex procedure with the potential to damage mentalis muscle and mental nerve, to affect chin growth, and prolonged recovery. Our...

متن کامل

ارزیابی و مقایسه عوارض وتمامیت فیستول شریانی- وریدی باگرافت گورتکس 6 و 8 میلی‌متری در اندام فوقانی و مقایسه آن‌ها با گرافت گورتکس 8 میلی‌متری اندام تحتانی در یک سال اول پس از عمل

Background & Aims: This study was done in hem dialysis patients who referred to Imam Khomeini hospital of Urmia for insertion of arterial -venous fistula with Gore-tex, in whom there was not possibility of natural fistula. Objectives were assessment and comparison of complications and patency of arterial-venous fistulas was done with 6 and 8 mm Gore-tex graft in the upper limb and comparison of...

متن کامل

Nasal augmentation using Gore-Tex. A 10-year experience.

OBJECTIVE To determine on an ongoing basis the safety and efficacy of expanded polytetrafluoroethylene (Gore-Tex soft tissue patch and preformed nasal implants) as an implant in rhinoplasty. DESIGN A retrospective study of 309 consecutive patients who underwent rhinoplasty, including augmentation with Gore-Tex, during a 10-year period. SETTING Two major academic medical centers and 2 privat...

متن کامل

Problems Associated with Alloplastic Materials in Rhinoplasty

PURPOSE Augmentation rhinoplasty using alloplastic materials is a relatively common procedure among Asians. Silicon, expanded polytetrafluoroethylene (Gore-tex®), and porous high density polyethylene (Medpor®) are most frequently used materials. This study was conducted to analyze revisional rhinoplasty cases with alloplastic materials, and to investigate the usage of alloplastic materials and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Archives of facial plastic surgery

دوره 5 3  شماره 

صفحات  -

تاریخ انتشار 2003