Performance of confocal scanning laser tomograph Topographic Change Analysis (TCA) for assessing glaucomatous progression.
نویسندگان
چکیده
PURPOSE To determine the sensitivity and specificity of confocal scanning laser ophthalmoscope's Topographic Change Analysis (TCA; Heidelberg Retina Tomograph [HRT]; Heidelberg Engineering, Heidelberg, Germany) parameters for discriminating between progressing glaucomatous and stable healthy eyes. METHODS The 0.90, 0.95, and 0.99 specificity cutoffs for various (n=70) TCA parameters were developed by using 1000 permuted topographic series derived from HRT images of 18 healthy eyes from Moorfields Eye Hospital, imaged at least four times. The cutoffs were then applied to topographic series from 36 eyes with known glaucomatous progression (by optic disc stereophotograph assessment and/or standard automated perimetry guided progression analysis, [GPA]) and 21 healthy eyes from the University of California, San Diego (UCSD) Diagnostic Innovations in Glaucoma Study (DIGS), all imaged at least four times, to determine TCA sensitivity and specificity. Cutoffs also were applied to 210 DIGS patients' eyes imaged at least four times with no evidence of progression (nonprogressed) by stereophotography or GPA. RESULTS The TCA parameter providing the best sensitivity/specificity tradeoff using the 0.90, 0.95, and 0.99 cutoffs was the largest clustered superpixel area within the optic disc margin (CAREA(disc) mm(2)). Sensitivities/specificities for classifying progressing (by stereophotography and/or GPA) and healthy eyes were 0.778/0.809, 0.639/0.857, and 0.611/1.00, respectively. In nonprogressing eyes, specificities were 0.464, 0.570, and 0.647 (i.e., lower than in the healthy eyes). In addition, TCA parameter measurements of nonprogressing eyes were similar to those of progressing eyes. CONCLUSIONS TCA parameters can discriminate between progressing and longitudinally observed healthy eyes. Low specificity in apparently nonprogressing patients' eyes suggests early progression detection using TCA.
منابع مشابه
Optic disc progression in glaucoma: comparison of confocal scanning laser tomography to optic disc photographs in a prospective study.
PURPOSE To compare confocal scanning laser tomography (CSLT) to optic disc photography for detecting progressive glaucomatous disc changes. METHODS Four expert observers first examined a training set of 40 pairs of monoscopic disc photographs to help set a criterion for change. They then classified 44 pairs of monoscopic photographs of patients followed prospectively as having either definite...
متن کاملImproving the repeatability of topographic height measurements in confocal scanning laser imaging using maximum-likelihood deconvolution.
PURPOSE To evaluate maximum likelihood (ML) blind deconvolution as a technique for improving the repeatability of topographic height measurements obtained from scanning laser tomography (Heidelberg Retinal Tomograph [HRT]; Heidelberg Engineering, Heidelberg, Germany). METHODS ML blind deconvolution is an image-processing technique that estimates the original scene from a degraded image. This ...
متن کاملClinical Significance of Optic Disc Progression by Topographic Change Analysis Maps in Glaucoma: An 8-Year Follow-Up Study
Aim. To investigate the ability of Heidelberg Retina Tomograph (HRT3) Topographic Change Analysis (TCA) map to predict the subsequent development of clinical change, in patients with glaucoma. Materials. 61 eyes of 61 patients, which, from a retrospective review were defined as stable on optic nerve head (ONH) stereophotographs and visual field (VF), were enrolled in a prospective study. Eyes w...
متن کاملTechnique for detecting serial topographic changes in the optic disc and peripapillary retina using scanning laser tomography.
PURPOSE To describe and evaluate a new statistical technique for detecting topographic changes in the optic disc and peripapillary retina measured with confocal scanning laser tomography. METHODS The 256x256-pixel array of topographic height values obtained with each image from the Heidelberg Retina Tomograph (Heidelberg Engineering, Heidelberg, Germany) was divided into an array of 64x64 sup...
متن کاملLocalized glaucomatous change detection within the proper orthogonal decomposition framework.
PURPOSE To detect localized glaucomatous structural changes using proper orthogonal decomposition (POD) framework with false-positive control that minimizes confirmatory follow-ups, and to compare the results to topographic change analysis (TCA). METHODS We included 167 participants (246 eyes) with ≥4 Heidelberg Retina Tomograph (HRT)-II exams from the Diagnostic Innovations in Glaucoma Study...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 50 2 شماره
صفحات -
تاریخ انتشار 2009