Droplets produced by medical nebulizers. Some factors affecting their size and solute concentration.
نویسندگان
چکیده
The effect of nebulizer solution temperature and dilution air humidity on the size and solute concentration of aqueous aerosol droplets were studied. Four combinations of jet-nebulizers with air compressors or oxygen sources and one ultrasonic nebulizer were tested. The temperature to which the nebulizer solution of each system fell during generation was measured. The nebulizers were then kept at set temperatures, generated aerosols collected and either droplet size or solute concentration measured. The droplet solute concentration was found to increase. The droplet size decreased along with the droplet solute concentration increase. The ultrasonic nebulizer also was tested: its high output made the concentration of the solution in the droplets much more stable. However, the proportion of droplets depositing in the tubing and valves changed markedly with aerosol flow rate. The potential for large changes in droplet solute concentration, droplet size and output during nebulization should be considered in therapeutic and diagnostic applications of nebulized aerosols.
منابع مشابه
Investigating and Mathematical Correlation of the Presence Effect of Solute and Surfactant on Mean Drop size in a Mixer-Settler
In this paper, the effects of several factors such as surfactant concentration, solute concentration, impeller speed and holdup on the mean drop diameter ( ) during emulsification have been studied in a single-stage mixer-settler extractor. A video technique has been developed in order to measure drop size distribution in the mixing chamber using a digital camera. The results show decreases wi...
متن کاملEvaluation of a nanosuspension formulation prepared through microfluidic reactors for pulmonary delivery of budesonide using nebulizers
This study aimed to determine the aerosolization behavior of a nanodispersion of budesonide, prepared using microfluidic reactors. The size and morphology of budesonide nanoparticles were characterized by photon correlation spectroscopy (PCS) and transmission electron microscopy (TEM). Processing/formulation parameters for formation of the nanoparticles were studied to determine their effects o...
متن کاملMicrostructure and Grain Refining Performance of a New Al-Ti-C Master Alloy (RESEARCH NOTE)
Control of microstructure parameters that affecting the Al-Ti-C master alloys grain refining efficiency is leading to improve the aluminum grain refinement. This study was an attempt to produce Al-Ti-C master alloys that provide these controlling factors with relying on the solute effect theory. The produced master alloys were examined by using scanning electron microscopy (SEM), energy-dispers...
متن کاملNebulizer testing
Two major factors affect drug delivery with nebulizers: usage time and droplet size. Unlike other inhalation devices, nebulizers provide continuous delivery instead of a pre-metered dose of drug. Once loaded and activated, a nebulizer operates with the user breathing normally so that the patient’s breathing profile and usage time determine the amount of drug received. As with other inhalation p...
متن کاملModeling of precipitate formation in precursor droplets injected axially into an oxygen/acetylene combustion flame
A computational heat and mass transfer model of ceramic precursor solution containing droplets injected into a combustion flame is presented. Upon heat-up and vaporization, the precursor in droplets precipitate and ultimately form the ceramic material. Temperature and solute concentration distributions were computed to estimate the precipitation zones within droplets based on a simple homogeneo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 97 6 شماره
صفحات -
تاریخ انتشار 1990