High-precision measurements
نویسنده
چکیده
Power converters in the accelerator context are often required to deliver a performance that is unusual in an industrial context. This paper deals with some of the important aspects of high-precision output voltage and current control and in particular the current measurement transducers and their application.
منابع مشابه
Water Velocity Measurements in Open Channels Using Volumetric Current Meter (VCM)
An innovative Volumetric Current Meter (VCM) was designed in order to allow quick velocity measurements in open channels. At first, the coefficient of velocity (Cv) of the device was determined through calibration under different water velocities in the laboratory. The measurement performance was verified by measurements performed in similar flows in irrigation channels using an ordinary curren...
متن کاملComparative Harmonic Loss Measurement of Grain Oriented and Non-oriented Magnetic Sheets Using a High Precision Single Sheet Tester
Abstract: Local flux may be distorted in many regions of core, although total flux is usually sinusoidal. When attempting to predict the loss distribution in materials operating under localized distorted flux conditions, which occur in machines and transformer cores, it is essential that proper account of the waveform be taken. Moreover for development of new magnetic materials and generation ...
متن کاملLeast Squares Techniques for GPS Receivers Positioning Filter using Pseudo-range and Carrier Phase Measurements
In present study, using Least Squares (LS) method, we determine the position smoothing in GPS single-frequency receiver by means of pseudo-range and carrier phase measurements. The application of pseudo-range or carrier phase measurements in GPS receiver positioning separately can lead to defects. By means of pseudo-range data, we have position with less precision and more distortion. By use of...
متن کاملAccuracy and precision of measurements obtained from conventional cephalograms and CBCT scan in orthodontics linear diagnostic measurements
Background and Purpose: Due to the important role of imaging in the diagnosis and treatment plan in orthodontics, CBCT (Cone Beam Computed Tomography) images because of their three-dimensional nature, can minimize the disadvantages of two-dimensional images such as magnification, distortion, or superimposition. The purpose of this study was to evaluate the accuracy of conventional cephalograms...
متن کاملElectroweak Precision Tests at GigaZ
By running the prospective high-energy ee collider TESLA in the GigaZ mode on the Z resonance, experiments can be performed on the basis of more than 10 Z events. This will allow the measurement of the effective electroweak mixing angle to an accuracy of δ sin θeff ≈ ±1×10. The W boson mass is likewise expected to be measurable with an error of δMW ≈ ±6 MeV near the WW threshold. We review the ...
متن کاملEffect of Welding Parameters in the Microstructure and Mechanical Properties of Friction-Welded Joints of 100Cr6 Steel
In this study, high-carbon, chromium alloy steel (100Cr6) having the initial spheroidized microstructure was welded using the rotary friction welding method. The effects of process parameters such as friction time and friction force were experimentally investigated. The friction welded joints were produced of two 100Cr6 steel rods. In order to examine the microstructure and mechanical properti...
متن کامل