Droplet sampling of an oil-based and two water-based antievaporant ultra-low volume insecticide formulations using Teflon- and magnesium oxide-coated slides.
نویسندگان
چکیده
We estimated the diameters below which 50% and 90% of the volume of droplets exist (Dv50 and Dv90, respectively) of 1 oil-based (Permanone 30-30) and 2 water-based (AquaReslin, Aqua-K-Othrine) antievaporant aerosols (with the Film Forming Aqueous Spray Technology [FFAST]) using Teflon- and magnesium oxide (MgO)-coated slides and determined whether the aging of the droplets on the slides (up to 60 min) exhibited any significant effect on Dv50 and Dv90 calculations. There were no significant differences in either Dv50 or Dv90 estimates on MgO-coated slides at 0 min and 60 min for all 3 products tested. On Teflon-coated slides, the only product that showed significant difference between 0 min and 60 min in both Dv50 and Dv90 estimates was Aqua-K-Othrine, perhaps due to a difference in formulation components. Specifically, both values corresponding to Dv50 and Dv90 at 60 min decreased by approximately 50% when compared to the values at 0 min. For the other 2 products, AquaReslin and Permanone, aging of droplets on Teflon up to 60 min did not have any significant effect on Dv50 and Dv90 values. To further investigate the behavior of Aqua-K-Othrine droplets on Teflon-coated slides we observed the droplets immediately after spraying and at 10-min intervals under different conditions of temperature and humidity. The majority of the shrinkage occurred within the 1st 10 min after impaction on the slides under all conditions tested. So in most field situations where slides are read several hours or days after collection, this shrinkage would not be observed. The MgO-coated slides should be the preferred field method for sampling droplets of Aqua-K-Othirne with the FFAST antievaporant technology.
منابع مشابه
Operational Note Temporal and Storage Effects on Ultra-low Volume Droplets of Insecticides Collected on Teflonh-coated Slides
Use of microscope slides is the most commonly used method to field-assess the droplet spectrum of ultra-low volume (ULV) sprays. Due to absence of analysis facilities during military deployments, slides must be stored and shipped, and the impact of delays in processing and storage conditions on droplets is unknown. This study was designed to evaluate the effect of storage temperatures and durat...
متن کاملOperational Note Samplers for Evaluation and Quantification of Ultra-low Volume Space Sprays
A field study was conducted to explore the suitability of 5 pesticide deposition samplers for airborne spray and ground deposits from ultra-low-volume (ULV) space sprays. Samplers included horizontally stretched stationary cotton ribbons at 2 heights, rotating ribbon, rotating Teflon slides, and filter paper. Slides were also used for droplet-size analysis. A set of 7 samplers of each type was ...
متن کاملSamplers for evaluation and quantification of ultra-low volume space sprays.
A field study was conducted to explore the suitability of 5 pesticide deposition samplers for airborne spray and ground deposits from ultra-low-volume (ULV) space sprays. Samplers included horizontally stretched stationary cotton ribbons at 2 heights, rotating ribbon, rotating Teflon slides, and filter paper. Slides were also used for droplet-size analysis. A set of 7 samplers of each type was ...
متن کاملA comparison of Teflon slides and the Army Insecticide Measuring System for sampling aerosol clouds.
The effects of method of droplet analysis, reader of Teflon slides and distance on mass median diameter of a Cythion aerosol cloud were examined in the calibration of an Army Insecticide Measuring System (AIMS). There were no significant differences in results among readers and between the AIMS and readers. There were slight but statistically significant differences between readers of Teflon sl...
متن کاملSpray characterization of thermal fogging equipment typically used in vector control.
Droplet size spectra from different sprayers used to generate insecticide-laden fogs for controlling flying insects were measured by a laser diffraction instrument and Teflon-coated slides. The objectives of this work were to present not only information on spray-system droplet size generated by different sprayers, but to compare methodologies by which other similar systems can be evaluated and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of the American Mosquito Control Association
دوره 29 2 شماره
صفحات -
تاریخ انتشار 2013