Assessment of accuracy and applicability of a portable electronic diary card spirometer for asthma treatment.

نویسندگان

  • I Godschalk
  • H J Brackel
  • J C Peters
  • J M Bogaard
چکیده

A pocked-sized turbine flowmeter and spirometer device, integrated with an electronic diary card (EDC-spirometer, Micro Medical, U.K.), was tested with a mechanical calibrator, in an outpatient clinic and in the home situation. A screen pneumotachometer was used as flow and volume reference. Ten devices were tested; interdevice variability was small with a mean variation coefficient of 1.1% for both forced expiratory volume in 1 s (FEV1) and peak expiratory flow (PEF) (SD 0.5 and 0.4, respectively) for eight settings of the calibrator. Mean difference from reference was -0.13 l (SD 0.04) for FEV1 (range 0.38-3.16) and 0.09 l s-1 (SD 0.09) for PEF (range 4.2-11.7). No significant deviation from linearity was present. Results obtained in the outpatient clinic confirmed the accuracy of FEV1 and PEF data obtained with the calibrator. However, linear regression analysis showed a mean underestimation of 0.45 l (SD of estimate 0.29) for forced vital capacity over the whole measurement range, probably due to a restricted integration time. In 10 optimally-treated chronic obstructive pulmonary disease patients in a family practice, PEF measurements were done in the home situation, both with the EDC spirometer and a mini-Wright peak flow meter. No significant differences in the diurnal variation of PEF were found. The PEF data from the mini-Wright meter were corrected for earlier reported flow-dependent systematic deviations. In the home situation, patients preferred the EDC spirometer. It is concluded that this device is applicable in the follow-up and treatment of asthma at home.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Asthma Control Level Assessment by Moving from the Current Reactive Care Models into a Preventive Approach based on Fuzzy Clustering and Classification Algorithms

Background and Aim: Asthma is a common and chronic disease of respiratory tracts. The best way to treat Asthma is to control it. Experts of this field suggest the continues monitoring on Asthma symptoms and adjustment of self-care plan with offering the preventive treatment program to have desired control over Asthma. Presenting these plans by the physician is set based on the control level in ...

متن کامل

Minimum data set for electronic health card of schizophrenia

Purpose: Having a clinical information system is a good solution for monitoring medical problems. This system is designed to improve the speed and accuracy of data management. The goal is to replace medical records with a clinical information system to support storing, processing and distributing data in all the sections of a healthcare center. The purpose of this research was to determine ...

متن کامل

Monitoring nebulizer use in children: comparison of electronic and asthma diary data.

BACKGROUND Measurement of nebulizer medication adherence that relies on self-report of medication use is subject to recall bias and increased patient burden. Electronic monitoring of nebulizer medication use is relatively new technology and provides an objective measure of nebulizer use. OBJECTIVE To examine levels of agreement for nebulizer use between self-report on diary cards and electron...

متن کامل

Night cough counts and diary card scores in asthma.

A tape recording system for recording night cough in asthmatics at home is described. Objective cough counts and half hour periods containing cough did not correlate with diary card scores awarded to eight children on seven nights each. Night cough diary scores may mislead in the assessment of symptom severity.

متن کامل

Is home monitoring of lung function worthwhile for children with asthma?

In this issue of Thorax Kamps et al point out that current guidelines for the management of asthma in children frequently advocate the use of home monitoring of lung function. This is supposed to provide an objective measurement of the status of the child’s asthma that can be used to guide therapy. This situation has come about partly as a “trickle down” from guidelines for managing asthma in a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory medicine

دوره 90 10  شماره 

صفحات  -

تاریخ انتشار 1996