Extraocular surgery for implantation of an active subretinal visual prosthesis with external connections: feasibility and outcome in seven patients.

نویسندگان

  • D Besch
  • H Sachs
  • P Szurman
  • D Gülicher
  • R Wilke
  • S Reinert
  • E Zrenner
  • K U Bartz-Schmidt
  • F Gekeler
چکیده

BACKGROUND Due to low energy levels in microphotodiode-based subretinal visual prostheses, an external power supply is mandatory. We report on the surgical feasibility and the functional outcome of the extraocular part of an approach to connect a subretinal prosthesis to an extracorporeal connector in the retro-auricular space via a trans-scleral, transchoroidal cable. METHODS Seven volunteers with retinitis pigmentosa received an active subretinal implant; energy was supplied by gold wires on a trans-sclerally, transchoroidally implanted polyimide foil leading to the lateral orbital rim where it was fixated and connected to a silicone cable. The cable was implanted subperiostally beneath the temporal muscle using a trocar to the retro-auricular space where it penetrated the skin for connection to a stimulator. To avoid subretinal movement of the implant, three tension relief points have been introduced. RESULTS All implantations were performed as planned without complications, and no serious adverse events occurred in the postoperative period. Fixation of the implants was stable throughout the entire study duration of 4 weeks; permanent skin penetration proved to be uncomplicated. Motility was minimally restricted in downgaze and ab-/adduction. Explantation was uneventful. CONCLUSION The above-described procedure provides a method for stable fixation of a subretinal device with a trans-scleral, transchoroidal cable connection to an extracorporeal connector.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Subretinal implantation of Okayama University-type retinal prosthesis (OURePTM) in canine eyes by vitrectomy

Okayama University-type retinal prosthesis (OURePTM) is a photoelectric dye-coupled polyethylene film which generates electric potential in response to light and stimulates nearby neurons. This study aims to test surgical feasibility of subretinal implantation and functional durability of dye-coupled films in the subretinal space. The dye-coupled films were implanted subretinally by 25-gauge vi...

متن کامل

Implantation of stimulation electrodes in the subretinal space to demonstrate cortical responses in Yucatan minipig in the course of visual prosthesis development.

PURPOSE During the course of the development of visual prostheses, subretinal stimulation films were implanted in micropigs in order to prove the feasibility of subretinal electrical stimulation with subsequent cortical response. One aim was to demonstrate that epidural recording of visual evoked potentials is possible in the micropig. METHODS Film-bound stimulation electrode arrays were plac...

متن کامل

Outcome Assessment after Aptis Distal Radioulnar Joint (DRUJ) Implant Arthroplasty

Background:  Conventional treatments after complicated injuries of the distal radioulnar joint (DRUJ) such as Darrach and Kapandji-Sauvé procedures have many drawbacks, which may eventually lead to a painful unstable distal ulna.  The development of DRUJ prosthesis has significantly evolved over the past years. In this study, we assessed the outcome results of patients after DRUJ implant arthro...

متن کامل

Radial Head Prosthesis Removal:a Retrospective Case Series of 14 Patients

Background:  The purpose of this study was to report the preoperative complaints and postoperative outcome of patients after removal of the radial head prosthesis.   Methods:  This is a retrospective review of 14 adult patients (6 females and 8 males) from 2007 to 2011, who underwent radial head prosthesis removal by three surgeons. The average time between implantation and removal was 23 month...

متن کامل

Implantation of Modular Photovoltaic Subretinal Prosthesis.

BACKGROUND AND OBJECTIVE Establish the surgical procedure for subretinal implantation of multiple photovoltaic arrays for the restoration of sight. MATERIALS AND METHODS Multiple silicon photovoltaic arrays of 1 mm in diameter and 30 µm in thickness were implanted subretinally via single retinotomy in rabbits. Ophthalmoscopic imaging and optical coherence tomography (OCT) were used to validat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of ophthalmology

دوره 92 10  شماره 

صفحات  -

تاریخ انتشار 2008