Imaging the vessel wall in major peripheral arteries using susceptibility-weighted imaging.

نویسندگان

  • Qi Yang
  • Jiantao Liu
  • Samuel R S Barnes
  • Zhen Wu
  • Kuncheng Li
  • Jaladhar Neelavalli
  • Jiani Hu
  • E Mark Haacke
چکیده

PURPOSE To demonstrate a novel contrast mechanism for imaging the vessel wall and vessel wall calcification using susceptibility-weighted imaging (SWI). MATERIALS AND METHODS Eighteen subjects were imaged with multidetector computed tomography (MDCT) and high-resolution SWI at 3T. The SWI imaging parameters were optimized to allow for the best visualization of the femoral artery lumen and the arterial wall in magnitude and phase images, respectively. SWI-filtered phase data were used to evaluate the diamagnetic susceptibility of vessel wall and of putative vessel wall calcification. Imaging was performed using TE = 15.6 msec (in-phase for fat); TR = 25 msec, flip angle (FA) = 10 degrees , bandwidth (BW) = 80 Hz/pixel, resolution = 0.5 x 0.5 mm in-plane and 1.0 mm through-plane, an acquisition matrix of 512 x 384 x 64 (for read, phase, and slice-select directions), and a total scan time of 8 minutes. RESULTS Nineteen calcifications were identified in CT and SWI and they correlated well in both size and position. The contrast-to-noise ratio between the blood signal in the lumen of the artery and arterial wall was 11.7:1 and 7.4:1 in magnitude and in phase images, respectively. CONCLUSION SWI provides a novel means to visualize vessel wall and recognize the presence of calcification.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Susceptibility Weighted Imaging and TOF-Angiography for the Detection of Thrombi in Acute Stroke

BACKGROUND AND PURPOSE Time-of-flight (TOF) angiography detects embolic occlusion of arteries in patients with acute ischemic stroke due to the absence of blood flow in the occluded vessel. In contrast, susceptibility weighted imaging (SWI) directly enables intravascular clot visualization due to hypointense susceptibility vessel signs (SVS) in the occluded vessel. The aim of this study was to ...

متن کامل

Monitoring of gadolinium uptake within the vessel wall during magnetic resonance (MR) guided angioplasty of the peripheral arteries with a paclitaxel/gadolinium coated balloon: an experimental study at 3 T

Methods 6 pigs (47±2 kg) were investigated. All experiments were performed using a 3 Tesla MRI system using a 6 channel coil. Iliaca-Interventions were performed using a preclinical paclitaxel/gadolinium coated balloon catheter and were monitored using a SSFP real-time imaging sequence. The feasibility of monitoring the delivery of paclitaxel/gadolinium to the vessel wall was assessed in 4 anim...

متن کامل

Imaging of carotid artery vessel wall edema using T2-weighted cardiovascular magnetic resonance

BACKGROUND Atherothrombosis remains a major health problem in the western world, and carotid atherosclerosis is an important contributor to embolic ischemic strokes. It remains a clinical challenge to identify rupture-prone atherosclerotic plaques before clinical events occur. Inflammation, endothelial injury and angiogenesis are features of vulnerable plaques and may all be associated with pla...

متن کامل

Study of Pulsatile Non-Newtonian Blood Flow Through Abdominal Aorta and Renal Arteries Incorporating Fluid- Structure Interaction

Background: The interaction between the blood and the vessel wall is of great clinical interest in studying cardiovascular diseases, the major causes of death in developed countries.Objective: To understand the effects of incorporating fluid-structure interaction into the simulation of blood flow through an anatomically realistic model of abdominal aorta and renal arteries reconstructed from CT...

متن کامل

Comparison Between Three-Dimensional Diffusion-Weighted PSIF Technique and Routine Imaging Sequences in Evaluation of Peripheral Nerves in Healthy People

Introduction: The present study aims to evaluate the Three-Dimensional Diffusion-Weighted reversed fast imaging with steady state free precession (3D DW-PSIF) sequence with respect to imaging of the peripheral nerves; the tibial, medial, and lateral plantar nerves in the lower extremity, ulnar and median nerve in the upper extremity, sciatic nerve, brachial plexus, and lumbosacral plexus, and a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 30 2  شماره 

صفحات  -

تاریخ انتشار 2009