Evaluation of the MicroScan Rapid Yeast Identification panel.

نویسندگان

  • G St Germain
  • D Beauchesne
چکیده

The MicroScan Rapid Yeast Identification (RYI) panel is a 4-h microdilution system for identification of clinical yeastlike isolates. Its accuracy was evaluated by using 357 isolates encompassing 11 genera and 30 species. The RYI panel identifications were compared with those obtained by the API 20C system assisted with morphological characterization on cornmeal-Tween 80 agar. The panels were read both visually and with the AutoScan-4, a computer-controlled microplate reader. Both the RYI panel and the API 20C system correctly identified 78% of the strains within 4 and 72 h, respectively, with no additional tests. Supplementary tests recommended by the manufacturers made it possible to identify up to 96.6% (AutoScan-4) and 98.9% (API 20C) of the strains. The accuracy of the RYI panel was 99.5% with common strains and 92.1% with less common strains. The RYI panel misidentified 10 or 12 strains and failed to identify 2 or 3 strains, depending on whether it was read with the AutoScan-4 or visually. Errors occurred with one strain of Torulopsis glabrata and the less common yeasts T. candida, Candida lusitaniae, C. lambica, C. rugosa, C. stellatoidea, Cryptococcus albidus, C. laurentii, and C. uniguttulatus. Overall, the RYI panel appears to be a reliable system for identification of the more common clinical yeast isolates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multicenter evaluation of the MicroScan Rapid Gram-Negative Identification Type 3 Panel.

The accuracy and performance of the revised MicroScan Rapid Gram-Negative Identification Type 3 Panel (Dade MicroScan Inc., West Sacramento, Calif.) were examined in a multicenter evaluation. The revised panel database includes data for 119 taxa covering a total of 150 species, with data for 12 new species added. Testing was performed in three phases: the efficacy, challenge, and reproducibilit...

متن کامل

Evaluation of MicroScan Rapid Pos Combo panels for identification of staphylococci.

MicroScan Rapid Pos Combo panels (Baxter Diagnostics, Inc., MicroScan, West Sacramento, Calif.) contain substrates conjugated with fluorophores and substrates with a fluorescent pH indicator. AutoSCAn W/A, an automated panel processor equipped with a fluorometer, reads the panels after 2 h of incubation and can identify staphylococci to the species level. We tested 239 strains belonging to 17 s...

متن کامل

Validation of Integral System Yeast Plus for rapid identification and determination of antifungal susceptibility profile of clinically important Candida species

Precise identification of microorganisms involved in candidiasis together with antifungal susceptibility evaluation could help clinicians to prescribe appropriate medicine, especially in patients with critical conditions. The present study has been conducted to evaluate discriminatory power of Integral System Yeast Plus (ISYP) for rapid identification and determination of antifungal susceptibil...

متن کامل

[Clinical significance on MicroScan Rapid plus series using various antibiotic-resistant bacteria].

MicroScan Rapid plus Neg II Series and MicroScan Rapid plus Pos Series by Siemens Healthcare Diagnostics K.K. are the panels which enable to measure identification and antimicrobial susceptibility testing quickly and we have confirmed that it is useful for detecting drug resistance bacteria. As the identification result of comparing Rapid plus series with the current panel by using 143 strains ...

متن کامل

Evaluation of the revised MicroScan dried overnight gram-positive identification panel to identify Enterococcus species.

The revised MicroScan Dried Overnight Gram-Positive Identification panel was evaluated for its efficacy at identifying Enterococcus species in comparison with conventional biochemical tests. Supplemental testing of ampicillin-susceptible Enterococcus faecium for motility and the ability to acidify methyl-alpha-D-glucopyranoside helped recognize E. gallinarum and increased the accuracy of the pa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 29 10  شماره 

صفحات  -

تاریخ انتشار 1991