Time-of-flight secondary ion mass spectrometry imaging of subcellular lipid heterogeneity: Poisson counting and spatial resolution.

نویسندگان

  • Paul D Piehowski
  • Angel M Davey
  • Michael E Kurczy
  • Erin D Sheets
  • Nicholas Winograd
  • Andrew G Ewing
  • Michael L Heien
چکیده

Mass spectrometric imaging is a powerful tool to interrogate biological complexity. One such technique, time-of-flight secondary ion mass spectrometry (TOF-SIMS) imaging, has been successfully utilized for subcellular imaging of cell membrane components. In order for this technique to provide insight into biological processes, it is critical to characterize the figures of merit. Because a SIMS instrument counts individual events, the precision of the measurement is controlled by counting statistics. As the analysis area decreases, the number of molecules available for analysis diminishes. This becomes critical when imaging subcellular features; it limits the information obtainable, resulting in images with only a few counts of interest per pixel. Many features observed in low intensity images are artifacts of counting statistics, making validation of these features crucial to arriving at accurate conclusions. With TOF-SIMS imaging, the experimentally attainable spatial resolution is a function of the molecule of interest, sample matrix, concentration, primary ion, instrument transmission, and spot size of the primary ion beam. A model, based on Poisson statistics, has been developed to validate SIMS imaging data when signal is limited. This model can be used to estimate the effective spatial resolution and limits of detection prior to analysis, making it a powerful tool for tailoring future investigations. In addition, the model allows comparison of pixel-to-pixel intensity and can be used to validate the significance of observed image features. The implications and capabilities of the model are demonstrated by imaging the cell membrane of resting RBL-2H3 mast cells.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Imaging subcellular features of a sectioned rat brain using time-of-flight secondary ion mass spectrometry and scanning probe microscopy

Coronal sections of unfixed rat brain samples were prepared on a flat substrate in order to revea hippocampal formation (CA1-4 pyramidal neurons) and adjacent neocortical white matter. We demonstrate the feasibility of using surface sensitive techniques such as time-of-flight secondary ion mass spectrometry (ToF-SIMS) and scanning probe microscopy (SPM) to probe lipid distribution, as wel as th...

متن کامل

Spatiotemporal lipid profiling during early embryo development of Xenopus laevis using dynamic ToF-SIMS imaging.

Time-of-flight secondary ion mass spectrometry (ToF-SIMS) imaging has been used for the direct analysis of single intact Xenopus laevis embryo surfaces, locating multiple lipids during fertilization and the early embryo development stages with subcellular lateral resolution (∼4 μm). The method avoids the complicated sample preparation for lipid analysis of the embryos, which requires selective ...

متن کامل

Direct molecular imaging of Lymnaea stagnalis nervous tissue at subcellular spatial resolution by mass spectrometry.

The imaging capabilities of time-of-flight secondary ion mass spectrometry (ToF-SIMS) and MALDI-MS sample preparation methods were combined. We used this method, named matrix-enhanced (ME) SIMS, for direct molecular imaging of nervous tissue at micrometer spatial resolution. Cryosections of the cerebral ganglia of the freshwater snail Lymnaea stagnalis were placed on indium-tin-oxide (ITO)-coat...

متن کامل

Secondary Ion Mass Spectrometry Imaging of Dictyostelium discoideum Aggregation Streams

High resolution imaging mass spectrometry could become a valuable tool for cell and developmental biology, but both, high spatial and mass spectral resolution are needed to enable this. In this report, we employed Bi3 bombardment time-of-flight (Bi3 ToF-SIMS) and C60 bombardment Fourier transform ion cyclotron resonance secondary ion mass spectrometry (C60 FTICR-SIMS) to image Dictyostelium dis...

متن کامل

Time‐of‐flight secondary ion mass spectrometry imaging of biological samples with delayed extraction for high mass and high spatial resolutions

RATIONALE In Time-of-Flight Secondary Ion Mass Spectrometry (TOF-SIMS), pulsed and focused primary ion beams enable mass spectrometry imaging, a method which is particularly useful to map various small molecules such as lipids at the surface of biological samples. When using TOF-SIMS instruments, the focusing modes of the primary ion beam delivered by liquid metal ion guns can provide either a ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 81 14  شماره 

صفحات  -

تاریخ انتشار 2009