Respiratory challenge induces high frequency spiking on the static charge sensitive bed (SCSB).
نویسندگان
چکیده
The static charge sensitive bed (SCSB) is a simple and noninvasive device used for the detection of sleep apnoea. In addition to episodes of apnoea or hypopnoea, heavy snorers commonly present with episodes of high frequency spiking on the SCSB. These spiking episodes have been claimed to represent partial upper airway obstruction during sleep, but the mechanism of their appearance is not known. We studied the SCSB spiking phenomenon in awake subjects during experimental respiratory challenge. One female and five male volunteers were studied whilst breathing freely, during hypoxia, hypercapnia and inspiratory and expiratory loading. Oxygen saturation, end-tidal carbon dioxide tension, minute ventilation, oesophageal pressure, electrocardiographic activity (ECG), blood pressure and the SCSB signals were monitored. During free breathing, the SCSB high frequency signal consisted of low amplitude complexes with close time relationship to the cardiac cycle. During respiratory challenge, spiking occurred. These spikes showed no time relationship to the cardiac cycle, but were time-linked to the onset of inspiration or expiration. Spike amplitude correlated with breathing frequency (r2 = 0.59; p < 0.005) and variation in oesophageal pressure (r2 = 0.57; p < 0.005). We conclude that during quiet, unobstructed breathing the static charge sensitive bed high frequency signal represents cardiac activity (ballistocardiogram), whereas during high-drive breathing high frequency spikes are produced. These spikes are respiratory in origin and are likely to represent fast components of respiratory movements. Our results support the use of static charge sensitive bed spiking as a noninvasive measure of breathing stimulation.
منابع مشابه
A Behavioral and Electrophysiological Assessment of Activity States Defined by Using the Static Charge Sensitive Bed (SCSB) Method
There is an obvious need in some fields of sleep research for objective methods which are less expensive and complicated than the standard procedure for defining sleep stages (1) or than the modern polysomnography (PSG) in which even more physiological parameters are used in addition to the EEG, EOG, and EMG recordings. The static charge sensitive bed (SCSB) is a movement sensor, also capable o...
متن کاملThe validity of the static charge sensitive bed in detecting obstructive sleep apnoeas.
The demand for polysomnographic recordings associated with respiratory control exceeds the capacity of the few existing sleep disorder centres and therefore a simple and inexpensive method is needed for screening and diagnosing sleep-related breathing disorders. The static charge sensitive bed (SCSB) permits long-term recordings of body movements, respiratory movements and the ballistocardiogra...
متن کاملA limited diagnostic investigation for obstructive sleep apnea syndrome. Oximetry and static charge sensitive bed.
A simplified sleep apnea investigation consisting of combined oximetry and respiration movement monitoring was compared with conventional polysomnography. These two types of recordings were performed simultaneously during one night in 77 patients with suspected obstructive sleep apnea syndrome (OSAS). A static charge sensitive bed (SCSB) was used in the simplified recording because it provides ...
متن کاملRespiratory variation of the ballistocardiogram during increased respiratory load and voluntary central apnoea.
Heavy snoring is associated with increased respiratory variation of the ballistocardiogram (BCG). The cause for this association is not known. Although the BCG is a sensitive method to measure myocardial performance, the validity of the signal as a marker of snoring-related haemodynamic changes has not been tested. The aim of this study was to investigate whether ballistocardiographic respirato...
متن کاملUpper airway size and collapsibility in snorers: evaluation with digital fluoroscopy.
This study addressed the question of whether there are any differences in the size and collapsibility of the upper airway measured by digital fluoroscopy, between snorers and controls whilst they were awake and breathing normally; and whether there are any correlations between these measurements and other clinical data. The dynamic changes of the upper airway size were evaluated using digital f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 9 9 شماره
صفحات -
تاریخ انتشار 1996