Response to comment on "Silicone wristbands as personal passive samplers".

نویسندگان

  • Steven G O'Connell
  • Susan E Carozza
  • Nancy I Kerkvliet
  • Kim A Anderson
چکیده

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Silicone Wristbands as Personal Passive Samplers

Active-sampling approaches are commonly used for personal monitoring, but are limited by energy usage and data that may not represent an individual's exposure or bioavailable concentrations. Current passive techniques often involve extensive preparation, or are developed for only a small number of targeted compounds. In this work, we present a novel application for measuring bioavailable exposu...

متن کامل

Accelerated solvent extraction (ASE) for purification and extraction of silicone passive samplers used for the monitoring of organic pollutants

Silicone passive samplers have gained an increasing attention as single-phased, practical and robust samplers for monitoring of organic contaminants in the aquatic environment in recent years. However, analytical challenges arise in routine application during the extraction of analytes as silicone oligomers are co-extracted and interfere severely during chemical analyses (e.g. gas chromatograph...

متن کامل

Application of silicone rubber passive samplers to investigate the bioaccumulation of PAHs by Nereis virens from marine sediments.

The availability of polycyclic aromatic hydrocarbons (PAHs) from marine sediments to the ragworm (Nereis virens) was studied. Concentrations of PAHs in pore waters were determined using silicone rubber passive samplers. Calculated bioconcentration factors confirmed that partitioning of PAHs between the lipid phase of the polychaetes and pore water is a passive process. Low biota-sediment accumu...

متن کامل

Characterization and Application of Passive Samplers for Monitoring of Pesticides in Water.

Five different water passive samplers were calibrated under laboratory conditions for measurement of 124 legacy and current used pesticides. This study provides a protocol for the passive sampler preparation, calibration, extraction method and instrumental analysis. Sampling rates (RS) and passive sampler-water partition coefficients (KPW) were calculated for silicone rubber, polar organic chem...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Environmental science & technology

دوره 48 15  شماره 

صفحات  -

تاریخ انتشار 2014