Equimolar ammonia interference in potassium measurement on the Osmetech OPTI CCA: a reply.

نویسندگان

  • Chao Lin
  • James K Tusa
چکیده

gate collection tubes from various manufacturers, available evidence, including our data, indicates that these problems may be common. The more rapid coagulation process in clot-activator tubes may be associated with more extensive proteolysis in the specimen, potentially leading to greater protein fragmentation that is subsequently detected by mass spectrometry. Nonbiological changes, observed repeatedly in the low-molecular-weight serum proteome profiles, raise the question of whether serum is the specimen of choice for major proteinand/or peptide-type clinical analytes such as hormones and tumor markers (8 ). In summary, clot activator-containing collection tubes may lead to preanalytical artifacts in proteomic studies. In our experience, these tubes can be effectively substituted with Li-heparin plasma tubes for chemistry analytes or plain serum tubes used for immunoassay and specimen banking.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Equimolar ammonia interference in potassium measurement on the Osmetech OPTI Critical Care Analyzer.

ter biological plausibility. Paradoxical values of decreases greater than 100% are eliminated. However, in view of monitoring applications, these RCVs are still rather high. The corrected lognormal RCVs refer to the commonly used 5% bidirectional statistical error. This RCV setup implies that 5% of clinically stable patients show changes greater than the RCV (false positives). However, for the ...

متن کامل

Use of the CDI blood parameter monitoring system 500 for continuous blood gas measurement during extracorporeal membrane oxygenation simulation.

UNLABELLED The Oximetrix III Opticath (Abbott Critical Care Systems) is used for continuous measurement of venous saturation in a variety of applications, including extracorporeal membrane oxygenation (ECMO), despite clinical reports that have presented data showing poor accuracy of these devices. The CDI Blood Parameter Monitoring System 500 (Terumo) is an inline blood gas monitoring tool comm...

متن کامل

The effect of hemodialysis on electrolytes and acid-base parameters.

BACKGROUND Hemodialysis patients are treated with bicarbonate dialysate to correct the metabolic acidosis, which results from the metabolism of dietary and endogenous protein. The concentration of plasma tCO(2) is used to gauge the success of therapy. Reported low values in pre-dialysis blood suggest incomplete correction of acidosis in a substantial percent of the dialysis population. However,...

متن کامل

Analysis of nitrate reductase mRNA expression and nitrate reductase activity in response to nitrogen supply

Nitrate is one of the major sources of nitrogen for the growth of plants. It is taken up by plant roots and transported to the leaves where it is reduced to nitrite in the. The main objective of this research was to investigate stimulatory effects of sodium nitrate, potassium nitrate, ammonia and urea on the production/generation of the nitrate reductase mRNA in Triticum aestivum plants. The pl...

متن کامل

A fluorescent chemosensor for calcium with excellent storage stability in water.

This article describes the design, synthesis and characterization of an optical sensor suitable for practical measurement of ionized calcium in serum and whole blood samples. The key to the development of this sensor is the identification of a chemically very stable, nitrogen-containing, calcium selective ionophore, coupled with a fluorophore having the correct spectral and electron accepting p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 52 11  شماره 

صفحات  -

تاریخ انتشار 2006