The two-catheter technique in indicator-dilution cardiovascular studies.
نویسندگان
چکیده
Indicator dilution technique is more widely used during cardiac catheterization for the diagnosis and rough estimate of the size of intracardiac shunts and valvular regurgitation (Korner and Shillingford, 1955; Fox and Wood, 1957; Swan and Wood, 1957; Woodward et al., 1957; Shillingford, 1958; Carter et al., 1959; Carleton et al., 1960; Jose et al., 1960). Evans blue dye (T-1824) has long been used to record dye dilution curves, being of special value in the diagnosis of right-to-left shunts (Falholt and Fabricius, 1958). However, this dye has the disadvantage of accumulation in human tissue and is influenced by the blood oxygen saturation; therefore, it cannot be used to record curves with venous blood. With the development of a new dye by Fox and Wood (1957) (tricarbocyanine dye II-cardiogreen)* it became possible to record indicator dilution curves from the right heart or venous circulation since this dye is not influenced by oxygen saturation of the blood. In the present study, we intend to report the usefulness of the dye dilution curve from the right side of the heart, using a two-catheter technique in patients with valvular regurgitation and left-to-right shunt in whom the blood oxygen saturation did not reveal an intracardiac shunt or adequately did not locate it. The dye dilution curve with injection into the right heart and sampling at the systemic artery does not provide information regarding location of a left-to-right shunt. It may but suggest the presence of a shunt; and in many cases it does not differentiate a curve due to valvular regurgitation from a curve of a patient with left-to-right shunt. In both circumstances, there is a prolonged disappearance curve with absence of a small recirculation curve. Thus, in order to make the indicator dilution technique useful in the diagnosis of a left-to-right shunt, injections and sampling sites have to be in the right heart.
منابع مشابه
Studies of coronary blood flow by multiple dye dilution curves.
The indicator-dilution technique has recently been applied to the study of the coronary circulation. One of the methods which have been proposed is the estimation of coronary blood flow from dilution curves sampled from the right ventricle after the injection of radio-iodinated human serum albumin into the left ventricle or into a catheter "wedged" in a branch of the pulmonary artery (1). Anoth...
متن کاملComparison of the accuracy of the lithium dilution technique with the thermodilution technique for measurement of cardiac output.
A new indicator dilution technique for measurement of cardiac output is described. Lithium chloride is injected via a central venous catheter and its dilution curve measured in arterial blood using a lithium-selective electrode. We assessed the lithium dilution cardiac output measurement (LiDCO) and a conventional thermodilution cardiac output measurement (ThDCO) by comparing the results of bot...
متن کاملContinuous cardiac output monitoring with pulse contour analysis: a comparison with lithium indicator dilution cardiac output measurement.
OBJECTIVE Pulse contour analysis can be used to provide beat-to-beat cardiac output (CO) measurement. The current study sought to evaluate this technique by comparing its results with lithium dilution CO (LiCO) measurements. DESIGN Prospective, observational study. SETTING Surgical intensive care unit. PATIENTS Twenty-two patients after cardiac or major noncardiac surgery. MEASUREMENTS ...
متن کاملSkin fold technique for central venous catheter fixation; Comparison with conventional method for postopration infections
Background: Central Venous Catheters (CVCs) are used not only as a tool to access to central venous system, but also for hemodynamic monitoring, parenteral nutrition, chemotherapy and hemodialysis. The use of CVCs is associated with some complications notably infections that are troublesome both to patient and physician. We conducted this study to examine catheter fixation with skin fold techni...
متن کاملA figure of merit for catheter sampling systems.
The distortion of indicator dilution curves by catheter sampling systems is predictable from theoretic considerations based on laminar flow. Over a wide range of catheter and flow parameters, deductions can be made regarding distortion, by the arterial system or by sampling catheters, of indicator dilution curves coming from an idealized pump. A figure of merit for the sampling system is given ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- British heart journal
دوره 23 شماره
صفحات -
تاریخ انتشار 1961