Repeatability and Reproducibility of Retinal Nerve Fiber Layer Parameters Measured by Scanning Laser Polarimetry with Enhanced Corneal Compensation in Normal and Glaucomatous Eyes
نویسندگان
چکیده
OBJECTIVE To assess the intrasession repeatability and intersession reproducibility of peripapillary retinal nerve fiber layer (RNFL) thickness parameters measured by scanning laser polarimetry (SLP) with enhanced corneal compensation (ECC) in healthy and glaucomatous eyes. METHODS One randomly selected eye of 82 healthy individuals and 60 glaucoma subjects was evaluated. Three scans were acquired during the first visit to evaluate intravisit repeatability. A different operator obtained two additional scans within 2 months after the first session to determine intervisit reproducibility. The intraclass correlation coefficient (ICC), coefficient of variation (COV), and test-retest variability (TRT) were calculated for all SLP parameters in both groups. RESULTS ICCs ranged from 0.920 to 0.982 for intravisit measurements and from 0.910 to 0.978 for intervisit measurements. The temporal-superior-nasal-inferior-temporal (TSNIT) average was the highest (0.967 and 0.946) in normal eyes, while nerve fiber indicator (NFI; 0.982) and inferior average (0.978) yielded the best ICC in glaucomatous eyes for intravisit and intervisit measurements, respectively. All COVs were under 10% in both groups, except NFI. TSNIT average had the lowest COV (2.43%) in either type of measurement. Intervisit TRT ranged from 6.48 to 12.84. CONCLUSIONS The reproducibility of peripapillary RNFL measurements obtained with SLP-ECC was excellent, indicating that SLP-ECC is sufficiently accurate for monitoring glaucoma progression.
منابع مشابه
Relationship between Scanning Laser Polarimetry with Enhanced Corneal Compensation and with Variable Corneal Compensation
PURPOSE To evaluate the structure-function relationships between retinal sensitivity measured by Humphrey visual field analyzer (HVFA) and the retinal nerve fiber layer (RNFL) thickness measured by scanning laser polarimetry (SLP) with variable corneal compensation (VCC) and enhanced corneal compensation (ECC) in glaucomatous and healthy eyes. METHODS Fifty-three eyes with an atypical birefri...
متن کاملAssessment of the retinal nerve fiber layer of the normal and glaucomatous monkey with scanning laser polarimetry.
PURPOSE To describe and test a method for assessment of the monkey retinal nerve fiber layer (RNFL) with scanning laser polarimetry. METHODS A scanning laser polarimeter was modified to accommodate a variable corneal polarization compensator. Corneal polarization magnitude (CPM) and corneal polarization axis (CPA) of the anterior segment birefringence of normal and glaucomatous cynomolgus mon...
متن کاملDiffuse glaucomatous structural and functional damage in the hemifield without significant pattern loss.
OBJECTIVES To compare the retinal nerve fiber layer (RNFL) thickness and retinal sensitivity in the normal visual hemifield of glaucomatous eyes with localized visual field loss with those of normal eyes and eyes with suspected glaucoma, and to evaluate the relationship between RNFL atrophy and glaucoma severity. METHODS One randomly selected eye of each subject underwent standard automated p...
متن کاملScanning laser polarimetry with variable corneal compensation and optical coherence tomography in normal and glaucomatous eyes.
PURPOSE To evaluate the relationship between visual function and retinal nerve fiber layer (RNFL) measurements obtained with scanning laser polarimetry with variable corneal compensation (SLP-VCC) and optical coherence tomography (OCT). DESIGN Cross-sectional analysis of normal and glaucomatous eyes in a tertiary care academic referral practice. METHODS A commercial GDx nerve fiber analyzer...
متن کاملIntraobserver Reproducibility of Retinal Nerve Fiber Layer Measurements Using Scanning Laser Polarimetry with Variable Corneal Compensation in Glaucoma Suspect Patients
Purpose: To quantify the intraobserver reproducibility of retinal nerve fiber layer (RNFL) measurements using scanning laser polarimetry with variable corneal compensation in glaucoma suspect patients. Methods: Twenty-six eyes of 26 glaucoma suspect patients were included. Complete ophthalmologic examination and standard automated perimetry were performed for all of them. RNFL measurements were...