Digital refraction distortion correction with an astigmatic coherence sensor.

نویسندگان

  • Daniel L Marks
  • Ronald A Stack
  • David J Brady
چکیده

We demonstrate the sensing and correction of an isoplanatic refractive distortion (not lens aberrations), using the complete measurement of the partially coherent field in an aperture that the previously described astigmatic coherence sensor provides. Isoplanatic distortions, and in general distortions that do not cause energy loss, maintain the orthogonality of the coherent modes. We use the fact that a common distortion will occur to all coherent modes to separate the distortion from the source behind it, rather than requiring a reference source at a different wavelength. Digital deconvolution was performed on the full four-dimensional partially coherent field for simultaneously computing the distortion and the source intensity distribution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Astigmatic coherence sensor for digital imaging.

We present a novel sensor that measures the entire spatial coherence function within an aperture by use of a variable astigmatic lens. This sensor permits digital capture and processing of partially coherent fields. We demonstrate the sensor by sampling and computing the coherent modes of a three-dimensional incoherent source.

متن کامل

Comparison of Astigmatic Correction after Femtosecond Lenticule Extraction and Small-Incision Lenticule Extraction for Myopic Astigmatism

PURPOSE To compare postoperative astigmatic correction between femtosecond lenticule extraction (FLEx) and small-incision lenticule extraction (SMILE) in eyes with myopic astigmatism. METHODS We examined 26 eyes of 26 patients undergoing FLEx and 26 eyes of 26 patients undergoing SMILE to correct myopic astigmatism (manifest astigmatism of 1 diopter (D) or more). Visual acuity, cylindrical re...

متن کامل

Laser in situ keratomileusis for astigmatism ≤ 0.75 Diopter combined with low myopia: a retrospective data analysis

BACKGROUND This study examined the refractive and visual outcome of wavefront-optimized laser in situ keratomileusis (LASIK) in eyes with low myopia and compound myopic astigmatism ≤ 0.75 diopter (D). METHODS 153 eyes from 153 consecutive myopic patients (74 male, 79 female; mean age at surgery 40.4 ± 10.4 years) who had a preoperative refractive cylinder ≤ 0.75 D and a manifest sphere betwee...

متن کامل

Autorefraction as an outcome measure of laser in situ keratomileusis.

PURPOSE To determine the limits of agreement between subjective refraction and autorefraction before and after laser in situ keratomileusis (LASIK) to assess whether autorefraction is a valid refractive outcome measure of refractive surgery. SETTING Ultralase, Leeds, United Kingdom. METHOD The prospective study involved consecutive preoperative normal patients and post-LASIK patients who ha...

متن کامل

The use of WaveLight® Contoura to create a uniform cornea: the LYRA Protocol. Part 2: the consequences of treating astigmatism on an incorrect axis via excimer laser

PURPOSE To show how an incorrect manifest astigmatism axis can cause an abnormal induced astigmatism on a new axis. PATIENTS AND METHODS Four eyes of three patients were treated primarily with WaveLight® EX500 wavefront optimized (WFO) treatments for astigmatism. All four eyes needed enhancements and were analyzed retrospectively via WaveLight® Contoura to determine the reason for the incorre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 41 29  شماره 

صفحات  -

تاریخ انتشار 2002