Rapid hydrophobic grid membrane filter-enzyme-labeled antibody procedure for identification and enumeration of Escherichia coli O157 in foods.
نویسندگان
چکیده
An O-antigen-specific monoclonal antibody, labeled by horseradish peroxidase-protein A, was used in a hydrophobic grid membrane filter-enzyme-labeled antibody method for rapid detection of Escherichia coli O157 in foods. The method yielded presumptive identification within 24 h and recovered, on average, 95% of E. coli O157:H7 artificially inoculated into comminuted beef, veal, pork, chicken giblets, and chicken carcass washings. In food samples from two outbreaks involving E. coli O157:H7, the organism was isolated at levels of up to 10(3)/g. The lower limit of sensitivity was 10 E. coli O157 per g of meat. Specific typing for E. coli O157:H7 can be achieved through staining with labeled H7 antiserum or tube agglutination.
منابع مشابه
Increased sensitivity of the rapid hydrophobic grid membrane filter enzyme-labeled antibody procedure for Escherichia coli O157 detection in foods and bovine feces.
Several strains of Escherichia coli O157:H7 artificially inoculated into vegetables and dairy products were recovered on hydrophobic grid membrane filters and enumerated by an enzyme-labeled antibody assay. The mean of the recoveries from 12 fresh vegetables was 108.8%, whereas that from 10 dairy products was 93.2%. Modified tryptic soy broth at 43 degrees C with shaking at 100 rpm provided opt...
متن کاملAntibody-direct epifluorescent filter technique for rapid, direct enumeration of Escherichia coli O157:H7 in beef.
Artificially inoculated Escherichia coli O157:H7 was directly enumerated in ground beef and beef exudate, without enrichment or selection, by the antibody-direct epifluorescent filter technique (Ab-DEFT). The total assay time of the Ab-DEFT was less than 1 h. The beef was homogenized, treated for 15 min with trypsin and Triton X-100, and passed through a 5-microns-pore-size prefilter and then t...
متن کاملDipstick immunoassay to detect enterohemorrhagic Escherichia coli O157:H7 in retail ground beef.
A sensitive and easy-to-perform dipstick immunoassay to detect Escherichia coli O157:H7 in retail ground beef was developed by using a sandwich-type assay (with a polyclonal antibody to E. coli O157 as the capture antibody and a monoclonal antibody to E. coli O157:H7 as the detection antibody) on a hydrophobic polyvinylidine difluoride-based membrane. E. coli O157:H7 in ground beef could be det...
متن کاملPreparation of monoclonal antibody and development of enzyme-linked immunosorbent assay specific for Escherichia coli O157 in foods.
OBJECTIVE To prepare monoclonal antibodies (MAb) and antisera specific for Escherichia coli (E. coli) O157, and to develop a sandwich enzyme-linked immunosorbent assay (ELISA) to detect E. coli O157 in foods. METHODS Spleen cells from BALB/c mice immunized with the somatic antigen of E. coli O157:H7 were fused with murine Sp2/0 myeloma cells. The hybridoma cell line specific for E. coli O157 ...
متن کاملEnumeration of Salmonella and Escherichia coli O157:H7 in ground beef, cattle carcass, hide and faecal samples using direct plating methods.
AIM To develop and validate high throughput methods for the direct enumeration of viable and culturable Salmonella and Escherichia coli O157:H7 in ground beef, carcass, hide and faecal (GCHF) samples from cattle. METHODS AND RESULTS The hydrophobic grid membrane filtration (HGMF) method and the spiral plate count method (SPCM) were evaluated as rapid tools for the estimation of pathogen load ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied and environmental microbiology
دوره 54 10 شماره
صفحات -
تاریخ انتشار 1988