Sensory testing of spinal anaesthesia for caesarean section: differential block and variability.

نویسندگان

  • M Kocarev
  • E Watkins
  • H McLure
  • M Columb
  • G Lyons
چکیده

BACKGROUND The aim of this study was to determine if sensory block following spinal anaesthesia, measured with a range of devices, corresponded to the hierarchy of nerve fibre size in the area of differential block, and to compare the distribution and variability of recorded measurements. METHODS Women with singleton pregnancies > 36 weeks of gestation undergoing elective caesarean section under combined spinal-epidural anaesthesia were recruited. An identical spinal anaesthetic was given to all. A single researcher with no clinical role assessed block height at 20 min from the time of spinal injection. Six tests were used in random order to measure four sensory modalities: ethyl chloride (cold), calibrated Neuropen (sharp), standardized monofilament 10 g (pressure), Neurotip stroking (light touch), monofilament stroking (light touch), cotton wool (light touch). The cost of each method of testing was noted. RESULTS The median differences between the four modalities were significant (Friedman test, P < 0.0001), but paired tests failed to find significant differences between Neuropen (sharp) and monofilament (pressure), monofilament (pressure) and Neurotip (light touch), and between tests for light touch. The tests for light touch had the least dermatomal spread and produced a unimodal distribution. The coefficient of variation was highest with ethyl chloride (24.1%) and the lowest with cotton wool (10.4%). CONCLUSIONS Sensory fibre hierarchy could be identified. Tests for light touch showed the least variability. More expensive tests do not appear to have any advantage over the least expensive test, cotton wool.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A randomised study of magnesium sulphate as an adjuvant to intrathecal bupivacaine in patients with mild preeclampsia undergoing caesarean section.

BACKGROUND Adequate analgesia following caesarean section decreases morbidity, hastens ambulation, improves patient outcome and facilitates care of the newborn. Intrathecal magnesium, an NMDA antagonist, has been shown to prolong analgesia without significant side effects in healthy parturients. We therefore studied the effect of adding intrathecal magnesium sulphate to bupivacaine-fentanyl spi...

متن کامل

Spinal anaesthesia for caesarean section: plain vs hyperbaric bupivacaine.

OBJECTIVE To compare the clinical characteristics of sensory and motor block as well as haemodynamic stability using plain and hyperbaric bupivacaine in spinal anaesthesia for caesarean section. METHODS Two equal groups were formed from a total of 60 patients who were enrolled in this prospective randomised double-blinded study that was done at tertiary care hospital in Karach, during 2005 to...

متن کامل

Comparative study of hyperbaric bupivacaine plus ketamine vs bupivacaine plus fentanyl for spinal anaesthesia during caeserean section.

BACKGROUND Spinal anesthesia is widely used for caesarean section due to its rapid onset, low failure rate, complete analgesia. Addition of intrathecal ketamine and opioids to local anaesthetics seems to improve the quality of block and prolong the duration of analgesia. OBJECTIVES The purpose of this study was to compare the effect of intrathecal ketamine mixed with hyperbaric bupivacaine to...

متن کامل

An unusually prolonged duration of spinal anaesthesia following 0.5% levobupivacaine.

Spinal anaesthesia is the method of choice for elective caesarean delivery. Levobupivacaine may produce a sensory and motor block that is different from that produced by bupivacaine, the most popular local anaesthetic for parturients undergoing caesarean section (CS). We present a case of unexpectedly prolonged spinal anaesthesia following a successful spinal block with levobupivacaine. There w...

متن کامل

Spinal anaesthesia with lidocaine 2% for caesarean section.

Spinal anaesthesia with 2, 2.5 or 3 ml of glucose-free lidocaine 2% was studied in 50 patients undergoing Caesarean section. Onset time, cephalad spread of analgesia, quality of analgesia, muscle relaxation, the cardiovascular effects and duration of analgesia and motor block were assessed. Reliable anaesthesia was provided with 2.5 and 3 ml while 2 ml of 2% lidocaine was insufficient. Onset ti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • International journal of obstetric anesthesia

دوره 19 3  شماره 

صفحات  -

تاریخ انتشار 2010