Comparison of the Mycobacteria Growth Indicator Tube (MGIT) with radiometric and solid culture for recovery of acid-fast bacilli.

نویسندگان

  • G E Pfyffer
  • H M Welscher
  • P Kissling
  • C Cieslak
  • M J Casal
  • J Gutierrez
  • S Rüsch-Gerdes
چکیده

In a multicenter study involving three reference centers for mycobacteria, the rate of recovery of acid-fast bacilli (AFB) and the mean time to their detection from clinical specimens was determined by using the Mycobacteria Growth Indicator Tube (MGIT). These parameters were compared to those assessed by the radiometric BACTEC 460 TB system and by cultivation on solid media. Clinical specimens (n = 1,500) were pretreated with N-acetyl-L-cysteine (NALC)-NaOH. The contamination rates for MGITs were 2.0% (center 1), 13.8% (center 2), and 6.1% (center 3). A total of 180 mycobacterial isolates were detected (M. tuberculosis complex, n = 113; nontuberculous mycobacteria [NTM], n = 67). When using a combination of liquid and solid media (the current "gold standard" for culture), MGIT plus solid media detected 156 (86.7%) of the isolates, whereas BACTEC plus solid media recovered 168 (93.3%) of all AFB. Between these two gold standards there was no statistically significant difference (P > 0.05). The combination of MGIT plus BACTEC detected 171 (95.0%) of all isolates (compared with MGIT plus solid media, P < 0.01; compared with BACTEC plus solid media, P > 0.05). Considering the efficacies of the different media separately, MGIT was superior to solid media (although not significantly; P > 0.05) in detecting AFB but was inferior to the BACTEC system (P < 0.01). The mean time to the detection of M. tuberculosis complex was 9.9 days with MGIT, 9.7 days with BACTEC, and 20.2 days with solid media. NTM needed, on average, 11.9, 13.0, and 22.2 days to appear by the three methods, respectively. In conclusion, MGIT proved to be a valuable alternative to the radiometric cultivation system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical evaluation of the Mycobacteria Growth Indicator Tube (MGIT) compared with radiometric (Bactec) and solid media for isolation of Mycobacterium species.

The aim of this study was to evaluate the clinical use of a new culture system for the isolation of mycobacteria. Routine clinical specimens were cultured in the Mycobacteria Growth Indicator Tube, the radiometric Bactec 460 TB system and on Lowenstein Jensen (LJ) medium to compare recovery rates and times for detection of mycobacteria and contamination rates. MGIT was tested for its ability to...

متن کامل

Pretreatment of clinical specimens with sodium dodecyl (lauryl) sulfate is not suitable for the mycobacteria growth indicator tube cultivation method.

When using the Mycobacteria Growth Indicator Tube (MGIT), pretreatment of clinical specimens with N-acetyl-L-cysteine-NaOH is recommended by the manufacturer. Processing of clinical specimens (n = 1,000) with sodium dodecyl (lauryl) sulfate-NaOH resulted in both poor recovery and delayed mean time to detection of acid-fast bacilli. Values were comparable to those obtained on solid media.

متن کامل

[Evaluation of combination of BACTEC mycobacteria growth indicator tube 960 system and Ogawa media for mycobacterial culture].

BACKGROUND The combined use of liquid media and solid media is recommended for mycobacterial culture. We evaluated diagnostic performance of combination of BACTEC Mycobacteria Growth Indicator Tube (MGIT; Becton Dickinson, USA) and 2% Ogawa media (Korean Institute of Tuberculosis, Korea) for recovery of mycobacteria. METHODS In September 2007, 1,764 specimens from 1,059 patients were cultured...

متن کامل

Use of the BACTEC Mycobacteria Growth Indicator Tube 960 automated system for recovery of Mycobacteria from 9,558 extrapulmonary specimens, including urine samples.

The BACTEC Mycobacteria Growth Indicator Tube 960 (MGIT 960) system was applied for recovery of mycobacteria from extrapulmonary specimens and compared with solid media (Löwenstein-Jensen and Stonebrink). A total of 9,558 specimens were investigated, comprising 3,074 body fluids, 1,878 tissues, and 2,069 urine samples, from which the recovery of mycobacteria was not yet established for MGIT 960...

متن کامل

Two liquid medium systems, mycobacteria growth indicator tube and MB redox tube, for Mycobacterium tuberculosis isolation from sputum specimens.

Two manual liquid medium systems, the Mycobacteria Growth Indicator Tube (MGIT) and MB Redox tube systems, were evaluated in comparison to the radiometric BACTEC-460 semiautomated system for recovery of Mycobacterium tuberculosis from sputum specimens. The highest level of recovery, from a total of 77 culture-positive specimens, occurred with the BACTEC-460 system (92.2%), followed by the MB Re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 35 2  شماره 

صفحات  -

تاریخ انتشار 1997