A new prototype of an electronic jet-ventilator and its humidification system
نویسندگان
چکیده
BACKGROUND: Adequate humidification in long-term jet ventilation is a critical aspect in terms of clinical safety. AIM: To assess a prototype of an electronic jet-ventilator and its humidification system. METHODS: Forty patients with respiratory insufficiency were randomly allocated to one of four groups. The criterion for inclusion in this study was respiratory insufficiency exhibiting a Murray score above 2. The four groups of patients were ventilated with three different respirators and four different humidification systems. Patients in groups A and B received superimposed high-frequency jet ventilation (SHFJV) by an electronic jet-ventilator either with (group A) or without (group B) an additional humidification system. Patients in group C received high-frequency percussive ventilation (HFPV) by a pneumatic high-frequency respirator, using a hot water humidifier for warming and moistening the inspiration gas. Patients in group D received conventional mechanical ventilation using a standard intensive care unit respirator with a standard humidification system. SHFJV and HFPV were used for a period of 100 h (4days). RESULTS: A significantly low inspiration gas temperature was noted in patients in group B, initially (27.2 +/- 2.5 degrees C) and after 2 days (28.0 +/- 1.6 degrees C) (P < 0.05). The percentage of relative humidity of the inspiration gas in patients in group B was also initially significantly low (69.8 +/- 4.1%; P < 0.05) but rose to an average of 98 +/- 2.8% after 2 h. The average percentage across all four groups amounted to 98 +/- 0.4% after 2 h. Inflammation of the tracheal mucosa was found in patients in group B and the mucosal injury score (MIS) was significantly higher than in all the other groups. Patients in groups A, C and D showed no severe evidence of airway damage, exhibiting adequate values of relative humidity and temperature of the inspired gas. CONCLUSION: The problems of humidification associated with jet ventilation can be fully prevented by using this new jet-ventilator. These data were sustained by nondeteriorating MIS values at the end of the 4-day study period in groups A, C and D.
منابع مشابه
Intelligent Knowledge Based System Approach for Optimization of Design and Manufacturing for Abrasive Water Jet Machining
A water jet machining is an industrial tool capable of cutting a wide variety of materials using a very high-pressure jet of water, or a mixture of water and an abrasive substance. This paper addresses the concept of the Intelligent knowledge base system (IKBS) for optimization of product design and manufacturing process for water jet machining in computer based concurrent engineering environme...
متن کاملIntelligent Knowledge Based System Approach for Optimization of Design and Manufacturing for Abrasive Water Jet Machining
A water jet machining is an industrial tool capable of cutting a wide variety of materials using a very high-pressure jet of water, or a mixture of water and an abrasive substance. This paper addresses the concept of the Intelligent knowledge base system (IKBS) for optimization of product design and manufacturing process for water jet machining in computer based concurrent engineering environme...
متن کاملComparison of jet and ultrasonic nebulizer pulmonary aerosol deposition during mechanical ventilation.
Increased delivery of aerosol to a model lung (attached to a mechanical ventilator) has been demonstrated with an ultrasonic nebulizer as compared to a jet nebulizer. This study examined whether the increased aerosol deposition with an ultrasonic nebulizer could also be demonstrated in vivo. Seven patients (6 male and 1 female) were studied during mechanical ventilalion (Siemens Servo 900C, Mid...
متن کاملLDA Experimental Data of Three-Poster Jet Impingement System
During its near-ground hovering phase a Short Take-Off and Vertical Landing (STOVL) aircraft creates a complex three-dimensional flow field between jet streams, the airframe surface and the ground. A proper understanding and numerical prediction of this flow is important in the design of such aircraft. In this paper an experimental facility, used to gather validation data suitable for testing C...
متن کاملCarbon dioxide entrainment during high-frequency oscillatory ventilation: a model analysis.
High-frequency ventilation got its start in the United States from a paper by Dr Mirosolav Klain, an anesthesiologist who described a high-frequency jet ventilator (HFJV)1 he built using a fluidic control circuit purchased as a demonstration kit from Corning Glass Works.2 Based on his description of the circuit, we built an HFJV and humidification system that we used to ventilate neonates clini...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Critical Care
دوره 3 شماره
صفحات -
تاریخ انتشار 1999