Measurement of Local Partial Pressure of Oxygen in the Brain Tissue under Normoxia and Epilepsy with Phosphorescence Lifetime Microscopy

نویسندگان

  • Cong Zhang
  • Samuel Bélanger
  • Philippe Pouliot
  • Frédéric Lesage
  • David C. Henshall
چکیده

In this work a method for measuring brain oxygen partial pressure with confocal phosphorescence lifetime microscopy system is reported. When used in conjunction with a dendritic phosphorescent probe, Oxyphor G4, this system enabled minimally invasive measurements of oxygen partial pressure (pO2) in cerebral tissue with high spatial and temporal resolution during 4-AP induced epileptic seizures. Investigating epileptic events, we characterized the spatio-temporal distribution of the "initial dip" in pO2 near the probe injection site and along nearby arterioles. Our results reveal a correlation between the percent change in the pO2 signal during the "initial dip" and the duration of seizure-like activity, which can help localize the epileptic focus and predict the length of seizure.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Frequency Multiplexed In Vivo Multiphoton Phosphorescence Lifetime Microscopy

Multiphoton microscopy (MPM) is widely used for optical sectioning deep in scattering tissue, in vivo [1-2]. Phosphorescence lifetime imaging microscopy (PLIM) [3] is a powerful technique for obtaining biologically relevant chemical information through Förster resonance energy transfer and phosphorescence quenching [4-5]. Point-measurement PLIM [6] of phosphorescence quenching probes has recent...

متن کامل

Three-dimensional mapping of oxygen tension in cortical arterioles before and after occlusion

Occlusions in single cortical microvessels lead to a reduction in oxygen supply, but this decrement has not been able to be quantified in three dimensions at the level of individual vessels using a single instrument. We demonstrate a combined optical system using two-photon phosphorescence lifetime and fluorescence microscopy (2PLM) to characterize the partial pressure of oxygen (pO2) in single...

متن کامل

Quantitating intracellular oxygen tension in vivo by phosphorescence lifetime measurement

Hypoxia appears to have an important role in pathological conditions in many organs such as kidney; however, a method to quantify intracellular oxygen tension in vivo has not been well established. In this study, we established an optical method to quantify oxygen tension in mice kidneys using a cationic lipophilic phosphorescence probe, BTPDM1, which has an intracellular oxygen concentration-s...

متن کامل

Red blood cell velocity and oxygen tension measurement in cerebral microvessels by double-wavelength photoexcitation.

Because the regulation of microcirculation in the cerebral cortex cannot be analyzed without measuring the blood flow dynamics and oxygen concentration in cerebral microvessels, we developed a fluorescence and phosphorescence system for estimating red blood cell velocity and oxygen tension in cerebral microcirculation noninvasively and continuously with high spatial resolution. Using red blood ...

متن کامل

Quantitative determination of localized tissue oxygen concentration in vivo by two-photon excitation phosphorescence lifetime measurements.

This study describes the use of two-photon excitation phosphorescence lifetime measurements for quantitative oxygen determination in vivo. Doubling the excitation wavelength of Pd-porphyrin from visible light to the infrared allows for deeper tissue penetration and a more precise and confined selection of the excitation volume due to the nonlinear two-photon effect. By using a focused laser bea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015