Evaluation of Anterior Segment Parameters and Possible Influencing Factors in Normal Subjects Using a Dual Scheimpflug Analyzer
نویسندگان
چکیده
PURPOSE To investigate normal anterior segment parameters and analyze the possible influencing factors using a dual Scheimpflug system. SETTING Department of Ophthalmology, Affiliated Sixth People's Hospital Shanghai Jiao Tong University, Shanghai, China. DESIGN A prospective observational case series. METHODS A total of 153 normal subjects (153 eyes) were studied. The anterior segment parameters, including the central corneal thickness (CCT), anterior chamber depth (ACD), pupil diameter (PD), keratoconus prediction index (KPI), simulated keratometry (SimK) values, anterior instantaneous curvature (AIC), posterior axial curvature (PAC), corneal eccentricity, total corneal power (TCP), axial curvature (AC), total corneal wavefront (TCW), high order aberration (HOA), and spherical aberration (SA), were determined using a dual Scheimpflug analyzer. RESULTS The CCT and ACD were both negatively correlated with age (r = -0.203, p = 0.012; r = -0.589, p<0.001). There was no significant difference in the refractive indices of AIC and SimK. Compared with the negative correlation of HOA and SA (r = -0.358, p<0.001), a positive correlation was found between TCW and HOA (r = 0.561, p<0.001). Unlike the decreased tendency of AC, the TCP increased gradually from the center to the periphery in the central 8 mm diameter. TCP showed a significant correlation with AC in the analyzed area. CONCLUSIONS AIC and SimK provide different information in clinic, but the refractive indices of them showed no difference in this healthy study population, and age should be considered when using CCT and ACD values.
منابع مشابه
Comparative Evaluation of Elevation, Keratometric, Pachymetric and Wavefront Parameters in Normal Eyes, Subclinical Keratoconus and Keratoconus with a Dual Scheimpflug Analyzer
Purpose: To compare the corneal parameters in normal corneas, forme fruste keratoconus (FFKC) and keratoconus measured with a dual Scheimpflug analyzer. Materials and methods: A total of 372 eyes of 197 patients were prospectively enrolled in the study and divided into three groups: 148 eyes of 102 patients with keratoconus, 47 contralateral topographically normal eyes of clinically evident ker...
متن کاملRepeatability and Reproducibility of Anterior Segment Measurements in Normal Eyes Using Dual Scheimpflug Analyzer
OBJECTIVES To assess the repeatability and reproducibility of anterior segment measurements including aberrometric measurements provided by a dual Scheimpflug analyzer (Galilei) system in normal eyes. MATERIALS AND METHODS Three repeated consecutive measurements were taken by two independent examiners. The following were evaluated: total corneal power and posterior corneal power, corneal high...
متن کاملRepeatability of Ocular Measurements with a Dual-Scheimpflug Analyzer in Healthy Eyes
PURPOSE To assess the repeatability of the Galilei dual Scheimpflug analyzer (GDSA) in anterior segment examination. METHODS Fifty-two eyes from 52 healthy volunteers were prospectively and consecutively recruited. Anatomic, axial, refractive, and instantaneous parameters were measured with GDSA to provide a complete characterization of the anterior segment. Repeatability was assessed calcula...
متن کاملRelationship among Corneal Biomechanics, Anterior Segment Parameters, and Geometric Corneal Parameters
Purpose. To investigate the relationship between corneal biomechanical parameters, anterior segment parameters, and geometric corneal parameters in a healthy Caucasian group. Methods. This retrospective study included the healthy eyes with best corrected visual acuity of at least 20/40 of 122 Caucasian subjects. The anterior segment parameters and geometric corneal parameters such as corneal vo...
متن کاملSingle session, intrauser repeatability of anterior chamber biometric and corneal pachy-volumetric parameters using a new Scheimpflug + Placido device
PURPOSE To analyze single session, intrauser reliability of a Scheimpflug device for anterior chamber (AC) and corneal parameters. METHODS In this observational study, 100 normal candidates underwent Scheimpflug analysis with Sirius 3D Rotating Scheimpflug Camera and Topography System (Costruzione Strumenti Oftalmici, Italy). Two scans in dark room conditions were performed by the same experi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 9 شماره
صفحات -