QFT-Plus: a plus in variability? – Evaluation of new generation IGRA in serial testing of students with a migration background in Germany

نویسندگان

  • J. Knierer
  • E. N. Gallegos Morales
  • A. Schablon
  • A. Nienhaus
  • J. F. Kersten
چکیده

BACKGROUND Currently available Interferon-gamma release assays (IGRAs) show a considerable variability in serial testing for latent tuberculosis infection (LTBI). This study offers first results for the new generation IGRA QuantiFERON-TB Gold Plus (QFT-Plus) introduced in 2015 in comparison with its predecessor QuantiFERON-TB Gold In-Tube (QFT-GIT) from serial testing of students with a migration background at German universities. METHODS Forty-one students were selected from a previous study. All students with a positive IGRA were asked and 11 agreed to participate in this cohort study. Additionally 30 students with negative IGRA results were selected by chance. Weekly testing with QFT-Plus and QFT-GIT was performed in all individuals over a 4-week period. IGRA variability was evaluated by calculating conversion and reversion rates. RESULTS From 41 participants a total number of 163 serial measurements were analyzed for each IGRA, leading to 122 possible IGRA changes each. QFT-Plus had four conversions and two reversions leading to a conversion rate of 4.3% (4 of 93 possible conversions, 95% CI 1.4-11.3%) and reversion rate of 6.9% (2 of 29 possible reversions, 95% CI 1.2-24.2%). QFT-GIT had 2 conversions and 1 reversion causing slightly lower rates with 2.2% conversions (2 of 91, 95% CI 0.4-8.5%) and 3.2% reversions (1 of 31, 95% CI 0.2-18.5%). Inconsistent IGRA results occurred in 4 subjects for QFT-Plus (8 stable positives, 29 stable negatives) and in 2 subjects for QFT-GIT (9 stable positives, 30 stable negatives). Agreement between the two IGRAs was 95.1% (κ = 0.89). Variance attributed to the individuals was low (QFT-Plus: ICC = 0.88). CONCLUSION This study confirms occurrence of conversions and reversions for the new QFT-Plus in serial testing of a high-risk cohort in a low-incidence setting with improbable new TB contact during the study. QFT-Plus conversion and reversion rates were slightly higher than for the QFT-GIT but overall they were lower for both IGRAs than in other studies that investigated IGRA variability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prevalence of latent tuberculosis infection among foreign students in Lübeck, Germany tested with QuantiFERON-TB Gold In-Tube and QuantiFERON-TB Gold Plus

BACKGROUND The tuberculosis (TB) incidence rate in foreign-born individuals has been increasing in Germany in recent years. Foreign students may be an important source of latent tuberculosis infection (LTBI) in low-incidence countries. In Germany, there are no guidelines for LTBI screening of foreign students. The aim of the study was to estimate LTBI prevalence and evaluate associated risk fac...

متن کامل

1685Screening for TB in Health Care Workers – QFT may not be the answer!

Background. Tuberculosis (TB) screening of healthcare workers (HCWs) is an important component of hospital infection control programs. Many institutions have replaced tuberculin skin tests (TSTs) with interferon-release gamma assays (IGRAs). Challenges of IGRA tests include daily fluctuations of IGRA values, serial testing variability, higher conversion rates of IGRAs than TSTs, and indetermina...

متن کامل

Specificity of a whole blood IGRA in German nursing students

BACKGROUND Interferon-gamma release assays (IGRA) are used for tuberculosis (TB) screening in healthcare workers (HCWs). However, data on specificity of IGRA in serial testing of HCWs is sparse. Therefore the specificity and the negative predictive value of the IGRA - QuantiFERON-TB Gold In-Tube (QFT) - in German nursing students was investigated. METHODS 194 nursing students at the start of ...

متن کامل

Predictors of persistently positive Mycobacterium-tuberculosis-specific interferon-gamma responses in the serial testing of health care workers

BACKGROUND Data on the performance of Mycobacterium-tuberculosis-specific interferon-(IFN)-gamma release assays (IGRAs) in the serial testing of health care workers (HCWs) is limited. The objective of the present study was to determine the frequency of IGRA conversions and reversions and to identify predictors of persistent IGRA positivity among serially tested German HCWs in the absence of rec...

متن کامل

Comparison study of QuantiFERON test with tuberculin skin testing to diagnose latent tuberculosis infection among nurses working in teaching hospitals of Ahvaz, Iran

Background: Prompt diagnosis and treatment of latent tuberculosis (TB) infection (LTBI) are needed to control TB. The aim of the study was to compare the performance of Quanti FERON-TB test (QFT) with conventional TST for the diagnosis of LTBI. Methods: In this analytical - comparison study, we enrolled 87 nurses working in teaching hospitals in Ahvaz. All study subjects were tested by TST.&...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017