Comparison of two microkeratome systems.

نویسندگان

  • P S Binder
  • M Moore
  • R W Lambert
  • D M Seagrist
چکیده

BACKGROUND Microkeratomes are currently used for keratomiluesis in situ (automated lamellar keratoplasty) for myopia and hyperopia and for laser in situ keratomileusis (LASIK). Visual and refractive complications have been reported with these refractive surgical procedures. We compared two microkeratomes in their ability to resect corneal lamellae to gain insight into possible mechanism(s) of refractive and visual complications following lamellar refractive procedures. METHODS Using an eyebank eye model, we performed automated lamellar keratoplasty to theoretically correct 10.00 diopters (D) of myopia using the Automated Corneal Shaper, manufactured by Chiron, Inc. and the MicroPrecision microkeratome, manufactured by Eye Technology, Inc. Diameters before (wet) and after fixation, thicknesses of excised tissue, and scanning electron microscopy were measured in a masked evaluation to compare instruments. Ultrasonic corneal pachymetry and a mechanical tissue compression gauge were also used to assess thickness of excised tissue. RESULTS The Chiron automated corneal shaper created blade chatter marks at the edges of all excisions, smaller than anticipated excision diameters, and a wide range of tissue thicknesses. In contrast, the MicroPrecision microkeratome created smoother resections of all tissues without creating blade marks; tissue diameters and thicknesses were closer to the intended dimensions compared to the Chiron automated corneal shaper. CONCLUSION Different microkeratomes create different morphologic features as they excise corneal tissue. Differences in instrument design, mechanics of the tissue excision and blade oscillation, and instrument traverse combined with surgical skill influence the configuration of lamellar keratotomies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of laser in situ keratomileusis flaps created by 3 femtosecond lasers and a microkeratome.

PURPOSE To evaluate the thickness and side-cut angle of laser in situ keratomileusis (LASIK) flaps created by 1 of 3 femtosecond lasers or a microkeratome using Fourier-domain optical coherence tomography (OCT). SETTING Department of Ophthalmology, Institute of Vision Research, Yonsei University College of Medicine, Seoul, Korea. DESIGN Comparative case series. METHODS Flap creation for b...

متن کامل

Comparison of higher-order aberration induction between manual microkeratome and femtosecond laser flap creation.

PURPOSE To compare the mean change in aberrations produced by a mechanical microkeratome and femtosecond laser. METHODS This was a retrospective study of 62 consecutive near emmetropic eyes that underwent LASIK and satisfied the following criteria: negligible laser ablation (for spherical equivalent of 0.00 to +0.50 diopters and maximum meridian of +0.50 diopters), and preoperative and at lea...

متن کامل

Comparison of the IntraLase femtosecond laser and mechanical microkeratome for laser in situ keratomileusis.

PURPOSE To compare clinical outcomes between the IntraLase femtosecond laser and the mechanical microkeratome for creating flaps during laser in situ keratomileusis. DESIGN Nonrandomized clinical trial. METHODS The study involved a total of 55 eyes of 30 patients, with 27 eyes of 16 patients comprising the microkeratome group and 28 eyes of 14 patients comprising the IntraLase group. Refrac...

متن کامل

In vivo corneal confocal microscopy comparison of intralase femtosecond laser and mechanical microkeratome for laser in situ keratomileusis.

PURPOSE To assess and compare corneal modifications induced by IntraLase PulsionFS femtosecond laser and mechanical microkeratome Hansatome for laser in situ keratomileusis (LASIK) using the new-generation Heidelberg Retina Tomograph II (HRT II)/Rostock Cornea Module confocal microscope. METHODS In this case-control study, 24 eyes of 12 patients were examined with the HRT II in the follow-up ...

متن کامل

Femtosecond laser versus mechanical microkeratome-assisted flap creation for LASIK: a prospective, randomized, paired-eye study

PURPOSE To compare a femtosecond laser with a microkeratome for flap creation during laser in situ keratomileusis (LASIK) in terms of flap thickness predictability and visual outcomes. PATIENTS AND METHODS This was a prospective, randomized, masked, paired-eye study. Forty-four patients (34 females) who received bilateral LASIK were included. Patients were stratified by ocular dominance, and ...

متن کامل

Refractive Surgery Focus on the Lasik Flap’s Creation

FEBRUARY 2010 CATARACT & REFRACTIVE SURGERY TODAY 49 MARK E. JOHNSTON, MD, FRCSC The three primary concerns with any microkeratome are safety, results, and cost. My colleagues and I have used the IntraLase FS laser (Abbott Medical Optics Inc., Santa Ana, CA) in more than 1,000 cases and the Zyoptix XP microkeratome (Technolas Perfect Vision, Saint Louis, MO) in over 10,000 cases. Both procedure...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 13 2  شماره 

صفحات  -

تاریخ انتشار 1997