New inhalation devices.

نویسنده

  • G K Crompton
چکیده

ll is now accepted that inhaled bronchodilator therapy is, whenever possible, to be preferred to oral treatment in the routine management of reversible airflow obstruction [1). However, during the last two decades we have repeatedly been reminded that many patients have great difficulty in using the conventional pressurized metered dose inhaler (MDI) [2-6], today's most frequently prescribed inhalation device. Inefficient use leads to decreased therapeutic efficacy [7], and it is possible, therefore, that at least half of our adult patients, and perhaps a greater proportion of children, are getting little or no benefit from using inhalers because of poor inhalation technique [6, 8, 9]. It appears that the magnitude of this problem has been appreciated, and recently new devices have been developed which should allow more patients to benefit from inhaled therapy in the future. It is unlikely that the MDI will be completely superseded by non-pressurized inhalers, but I believe that the future of the conventional MDI is limited. In the past this device has been modified in attempts to make it easier to use. The development of spacer systems was of great clinical importance [10], and large-volume spacers will continue to havp a role in the management of asthmatic patients in the; foreseeable future. Smallvolume extension spacer devices are of less value and may be replaced by the new inhalers. Spacer attachments were necessary to overcome the inherent problems of a pressurized inhalation system, which is critically dependent upon the patient's coordination of dose release with inspiration. Prior to the introduction of spacer systems a breathactuated pressurized inhaler "Autohaler" had been introduced into clinical practice [11]. Although this is bulky compared to the MDI, it is much smaller than the combination of an MDI .and a large-volume spacer, however, it has the disadvantage of generating a loud "click" when the valve mechanism is triggered. A generous inspiratory effort is also required to actuate the "Autohaler". For these reasons, and also because it was introduced containing isoprenaline as the bronchodilator, it has failed to secure a major share of the market. The concept of a breath-actuated pressurized aerosol is admirable, since the main problem of coordination of valve actuation and inspiration could be solved. On the other hand, the inability of some patients to continue to breathe in when propellant is released

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Metered dose inhalers and spacer devices.

Easy to carry, highly effective and extremely safe, allowing accurate, consistent dose delivery, metered dose inhalers are the inhalation devices doctors and patients choose most readily the world over. Clinical response, however, may be affected by the inhalation technique used and the precise formulation in the canisters. The purpose of this review is to consider metered dose inhalers, add on...

متن کامل

New frontiers in aerosol delivery during mechanical ventilation.

The scientific basis for inhalation therapy in mechanically-ventilated patients is now firmly established. A variety of new devices that deliver drugs to the lung with high efficiency could be employed for drug delivery during mechanical ventilation. Encapsulation of drugs within liposomes could increase the amount of drug delivered, prolong the effect of a dose, and minimize adverse effects. W...

متن کامل

Cultural and linguistic validation of the NHQ-2 Questionnaire: a specific instrument for assessing patient’s usability of inhalation devices

BACKGROUND An increasing number of inhalation devices are presently available in the market. They are differently characterized in terms of their handling and usability, both factors which may affect the outcomes of respiratory treatment. The assessment of the preference and the usability rate of all devices can be carried out by means of specific questionnaires. Before their use, the identific...

متن کامل

Comparing inhaled corticosteroids.

There are currently available 5 different inhaled corticosteroids, in a variety of different inhalation delivery devices. In the near future there will certainly be more inhaled corticosteroids in newer inhalation delivery devices available in the United States. Tremendous amounts of information will be made available about the relative advantages and disadvantages of these new products. Most o...

متن کامل

Predictors of incorrect inhalation technique in patients with asthma or COPD: a study using a validated videotaped scoring method.

BACKGROUND Inadequate technique reduces the effects of inhalation medication. Errors in inhalation technique have been reported to range up to 85%. Not only various patients' characteristics but also the device has an effect on correct inhalation technique. The purpose of this study was to determine the effect of patients' characteristics and type of inhaler device on inhalation technique in pa...

متن کامل

Usage of inhalation devices in asthma and chronic obstructive pulmonary disease: a Delphi consensus statement.

OBJECTIVES The study aimed to assess usage of inhalation devices in asthma and chronic obstructive pulmonary disease (COPD). METHODS In this two-round Delphi survey, 50 experts in asthma and COPD completed a 13-item, Internet-based, self-administered questionnaire about choice of inhalation device, training and monitoring of inhalation techniques, the interchangeability and the role of costs ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 1 8  شماره 

صفحات  -

تاریخ انتشار 1988