Ferritin immunosensing on microfabricated electrodes based on the integration of immunoprecipitation and electrochemical signaling reactions.
نویسندگان
چکیده
A signal registration strategy from micropatterned immunosensors that converts antigen-antibody binding reactions into electrochemical signals was demonstrated. An array-type micropatterned gold electrode on a silicon wafer was fabricated, containing two electrode geometries of rectangular (100 microm x 500 microm) and circular (r. 50 microm) types, exhibiting electrochemical characteristics of bulk and micro-electrodes, respectively. Ferritin was employed as a model analyte for immunosensing because it has an advantageous molecular structure for functionalization to the sensing interface, and is regarded as a general marker protein for tumors and cancer recurrence. With the fabricated and ferritin-functionalized immunosensors, biospecific interactions were performed with antiferritin antiserum and secondary antibody samples, followed by electrochemical signaling via an immunoprecipitation reaction by the label enzyme. Under the optimized affinity-surface construction steps and reaction conditions, both types of microfabricated electrodes exhibited well-defined calibration results as a function of the protein concentration in antiserum samples. Furthermore, circular-type micropatterned immunoelectrodes exhibited voltammetric characteristics of microelectrodes, which is advantageous in terms of sensor operation under a fixed potential and low signal drift during the signaling reaction compared with the bulk-type electrodes. The results support that the employed signaling method with the proposed immunosensor configuration is fit for sensor miniaturization and integration to future biomicrosystems.
منابع مشابه
Electrochemical magneto immunosensing of antibiotic residues in milk.
A novel electrochemical immunosensing strategy for the detection of sulfonamide antibiotics in milk based on magnetic beads is presented. Among the different strategies for immobilizing the class-specific anti-sulfonamide antibody to the magnetic beads--such as those based on the use of Protein A or carboxylate modified magnetic beads - ,the best strategy was found to be the covalent bonding on...
متن کاملImproved Mechanical and Electrochemical Properties of Artificial Graphite Anode Using Water-Based Binders in Lithium-Ion Batteries
In recent years, many studies have focused on the active materials of anodes to improve the performance of LIBs, while limited attention has been given to polymer binders, which act as inactive ingredients. However, polymer binders have amazing influence on the electrochemical performance of anodes. Herein, to investigate the binding performance between MCMB artificial graphite and the copper c...
متن کاملMicrofabricated Reference Electrodes and their Biosensing Applications
Over the past two decades, there has been an increasing trend towards miniaturization of both biological and chemical sensors and their integration with miniaturized sample pre-processing and analysis systems. These miniaturized lab-on-chip devices have several functional advantages including low cost, their ability to analyze smaller samples, faster analysis time, suitability for automation, a...
متن کاملTuning Electrodeposition Parameters for Tailored Nanoparticle Size, Shape, and Morphology: An In Situ ec-STEM Investigation
Advances in vacuum-tight in situ liquid cell TEM systems have attracted significant attention because of the ability to directly interpret chemical and electrochemical reactions within their native liquid environments [1]. Conducting quantitative in situ electrochemistry experiments within the S/TEM is feasible using the relatively new platform of in situ electrochemical S/TEM (ec-S/TEM). In th...
متن کاملStudy on Electrochemical Oxidation of m-Nitrophenol on Various Electrodes Using Cyclic Voltammetry
The electrochemical oxidation behavior of m-nitrophenol (m-NP) was studied comparatively on glassy carbon electrode, Pt electrode, PbO2 electrode, SnO2 electrode, and graphite electrode using cyclic voltammetry. The cyclic voltammetry measurements were performed in acidic (1 M H2SO4, pH 0.4), neutral (1 M Na2SO4, pH 6.8), and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 20 9 شماره
صفحات -
تاریخ انتشار 2004