Recalls and safety alerts affecting automated external defibrillators.
نویسندگان
چکیده
CONTEXT Automated external defibrillators (AEDs) play a key role in the community resuscitation of persons with cardiac arrest and are of proven clinical benefit. Although AEDs are complex medical devices designed to function during life-threatening emergencies, little is known about their reliability. OBJECTIVES To determine the number and rate of AED recalls and safety alerts, to identify trends in these rates, and to identify the types of malfunctions prompting AED and AED accessory advisories. DESIGN AND SETTING Analysis of weekly US Food and Drug Administration (FDA) Enforcement Reports between January 1996 and December 2005 was performed to identify all recalls and safety alerts (collectively referred to as "advisories") involving AEDs and AED accessories. Confirmed AED device malfunctions were identified by reviewing AED-related adverse events reported to the FDA. MAIN OUTCOME MEASURES Number of AEDs and AED accessories subject to FDA recall or safety alert between January 1996 and December 2005; annual AED advisory rates; and number of confirmed fatal AED-related device malfunctions reported to the FDA. RESULTS During 2.78 million AED device-years of observation, 52 advisories (median [25th and 75th percentiles], 4.5 [3.0 and 5.0] per year) affecting 385,922 AEDs and AED accessories were issued. The mean (SE) annual number of AEDs affected by advisories was 5.1 (1.5) devices per 100 AED device-years. Overall, 21.2% of AEDs distributed during the study period were recalled, most often because of electrical or software problems. The AED advisory rate did not significantly increase during the study period, although the annual number of AED advisories (P for trend =.02) and AED advisory devices (P for trend = .01) did increase. Confirmed fatal AED-related device malfunctions occurred in 370 patients. CONCLUSIONS Automated external defibrillators and AED accessory advisories occur frequently and affect many devices. Actual AED malfunctions do occur occasionally, although the number of observed malfunctions is small compared with the number of lives saved by these important devices. As the prevalence of AEDs continues to increase, the number of devices affected by advisories can also be expected to increase. Efforts should be directed at developing a reliable system to locate and repair potentially defective devices in a timely fashion.
منابع مشابه
Is your AED ready to shock?
There seems to be more news coverage these days about automated external defibrillator (AED) failures and device recalls by manufacturers. In March of this year, the U.S. Food and Drug Administration announced its intent to require new AEDs and accessories to go through a more rigorous approval process. The action is in response to recalls by manufacturers, documented failures, and adverse even...
متن کاملComparison of rates of safety issues and reporting of trial outcomes for medical devices approved in the European Union and United States: cohort study
OBJECTIVE To evaluate safety alerts and recalls, publication of key trial outcomes, and subsequent US approval of high profile medical devices introduced in the European Union. DESIGN Cohort study. SETTING Novel cardiovascular, orthopedic, and neurologic devices approved in the EU through Conformité Européenne marking between 2005 and 2010. DATA SOURCES Public and commercial databases...
متن کاملInvestigation of availability and accessibility of community automated external defibrillators in a territory in Hong Kong.
OBJECTIVE To evaluate the availability and accessibility of community automated external defibrillators in a territory in Hong Kong. DESIGN Cross-sectional study. SETTING Two public hospitals in New Territories West Cluster in Hong Kong. PARTICIPANTS Information about the locations of community automated external defibrillators was obtained from automated external defibrillator suppliers ...
متن کاملComparison of ease of use of three automated external defibrillators by untrained lay people.
The use of automated external defibrillators (AED) by lay people has the potential to markedly increase survival from community cardiac arrest. Wider public use of AEDs requires units that can be operated safely and effectively by people with minimal or no training. This study compares the use of three AEDs by untrained lay people regarding ease-of-use, safety, pad positioning and time to defib...
متن کاملA qualitative study to identify barriers to deployment and student training in the use of automated external defibrillators in schools
BACKGROUND Student training in use of automated external defibrillators and deployment of such defibrillators in schools is recommended to increase survival after out-of-hospital cardiac arrest. Low implementation rates have been observed, and even at schools with a defibrillator, challenges such as delayed access have been reported. The purpose of this study was to identify barriers to the imp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- JAMA
دوره 296 6 شماره
صفحات -
تاریخ انتشار 2006