Design of a Dynamically-Controlled Resistive Shield for a Combined PET and Superconducting MRI System for Small Animal Imaging

نویسندگان

  • G. A. Bindseil
  • T. J. Scholl
  • W. B. Handler
  • C. T. Harris
  • B. A. Chronik
چکیده

Introduction Efforts to combine anatomical and functional imaging modalities have resulted in the development and widespread use of PET/CT systems. PET/MRI would offer improved soft tissue contrast, highresolution anatomical information and would benefit longitudinal studies due to reduced dose. Combining conventional PET and MRI faces numerous technical challenges, particularly the sensitivity of photomultiplier tube-based (PMT) PET detectors to magnetic fields. Current approaches to PET/MRI typically (a) employ novel PET detectors immune to magnetic fields, or (b) place conventional PET detectors in a region of minimal magnetic field. An approach of the first type uses avalanche photodiodes (APD), which are unaffected by magnetic fields, in place of PMTs within an MR-compatible PET insert [1]. An example of the second type of approach was recently introduced by Philips, where a conventional human-scale PET system with passive magnetic shielding is separated by several meters from an otherwise normal MRI system. A single bed moves patients between the PET and MR imaging regions, analogous to PET/CT. In this abstract, we describe an approach in which a resistive electromagnet shield is used to null the field at the PMTs of a conventional PET system in the vicinity of an MRI system. The ability to use commercially available, highly optimized PET systems without major modification is a significant advantage of this approach. The design presented is based on the Siemens Inveon small-animal PET (Siemens Medical, Knoxville, TN) and a Magnex 2.0 T 310-mm-bore superconducting MRI, and is intended for small-animal imaging applications. The ability to have a single bed for the animal that can extend through both the MRI and PET systems without disconnection of monitoring equipment or anaesthetics was considered to be critical. Methods As indicated in Figure 1, a targeted shielding coil, placed between the two systems is energized during PET imaging to shield the PET detectors from the B0 field of the MRI system. During MR imaging, the shield is turned off. A moveable and extendible bed with 30-micron precision moves the animal between PET and MR fields of view along a rigid track without disturbing the animal’s position on the bed or disconnecting anaesthetic supply lines. Proof-of-principle tests have shown that linear and mesh PMTs recovered normal operation within several milliseconds of a magnetic field being turned off with no long-term effects [2]. In addition, the authors have found that the Siemens Inveon PET system suffers no permanent performance degradation after repeated exposure to magnetic fields of 11 mT. The PET detector consists of a ring of 16 modules, each consisting of a row of four LSO crystal blocks (1.59x1.59x10 mm crystals in 20x20 block) coupled to four Hamamatsu R8900 position-sensitive PMTs. During exposure to magnetic fields, the R8900 PMT suffers changes in gain and efficiency of approximately 10% at 0.3 mT (radial, xy) or 1.0 mT (axial, z) [3]. So long as the spatial field profile does not change with time, the PET system can be calibrated to account for this level of gain and efficiency change with negligible affect on performance. Therefore, our goal was to reduce the field at the PET detector ring to below 0.3 mT (radial) and 1.0 mT (axial). The targeted shield coil was designed using the boundary element method, with data for the MRI fringe field obtained from the manufacturer. A cylindrical ring of null-field targets extended 15 cm axially along the length of the 12-cm-long four-PMT module (1.5 cm buffer on either end) and extended from a radius of 8 cm (the face of the scintillator) to 14 cm (1 cm beyond the PMT). The distance between the center of the MRI system and the PET system was chosen to be 1.7 m. While larger separations would reduce power requirements, the range of bed motion must be short enough for cables and supply lines to remain connected between PET and MRI scans. Results The candidate shielding coil has radius 75 cm and length 60 cm and its front end is located 90 cm from the centre of the MRI system. The coil consists of a single layer of 34 variable-separation turns with a 10.7-mm minimum wire separation. The hollow wire to be used has 10x10-mm cross-section with a 5-mm-diameter liquid cooling channel. The characteristics of the shield coil are summarized in Table 1. The proposed design successfully reduces the maximum magnetic field at the location of the PMT detectors to better than 0.13 mT, as required. The power requirements for the coil are essentially equivalent to those of present-day insert gradient coil systems and would be acceptable for this application. Discussion The primary challenge in the operation of this system is certainly expected to be interaction between the shield and the superconducting magnet. The allowed distance between the PET and MRI systems directly affects the shield requirements and further tradeoffs are possible. It would also be possible to add a term in the algorithm cost-function that represents coupling between the shield and magnet. The result would be increased power deposition in the shield. The approach described in this abstract benefits from allowing the use of commercially available PET systems, which include state-of-the-art timing & energy resolution, high sensitivity, and highly optimized event processing hardware. The sensitivity of the PMT-based system to be used (10%) is substantially greater than that of PET systems used in current simultaneous approaches to PET/MRI (0.23% [1]), meaning faster PET imaging time or lower dose for longitudinal studies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PET and MRI-guided focused ultrasound surgery for hypoxic-tissue ablation combined with radiotherapy in solid tumors

Background: The rationale was to develop an ablation approach to destroy regions of tumor resistant to radiation and thus reduce the time required for whole tumor ablation, while improving overall tumor control after radiotherapy. Materials and Methods: The system is composed of a micro positron emission tomography (mPET), 7T magnetic resonance imaging (MRI), and a customized MRI-compatible foc...

متن کامل

Design of a Docking PET and Field-Cycled MRI System for Small Animal Imaging

Introduction Efforts to combine anatomical and functional imaging modalities have resulted in the successful development and widespread use of PET/CT systems. PET/MRI would offer substantially better soft tissue contrast, provide high-resolution anatomical information and would be beneficial for longitudinal studies. Combining conventional PET and superconducting MRI faces many technical challe...

متن کامل

An Optimal Design Approach for Resistive and Inductive Superconducting Fault Current Limiters via MCDM Techniques

The design process of a superconducting current limiter (SFCL) requires simulation and definition of its electrical, magnetic and thermal properties in form of equivalent circuits and mathematical models. However, any change in SFCL parameters: dimension, resistance, and operating temperature can affect the limiting mode, quench time, and restore time. In this paper, following the simulation of...

متن کامل

Design of Small Animal Computed Tomography Imaging for in vitro and in vivo Studies

Introduction: Mini Computed Tomography (mini-CT) was suggested in biomedical research to investigate tissues and small animals. We present designed and built a mini x-ray computed tomography (mini-CT) for small animals as well as industrial component imaging. Materials and Methods: The system used in this study includes a X-ray tube 20kV to 160kV and a flat pa...

متن کامل

New Pseudo-CT Generation Approach from Magnetic Resonance Imaging using a Local Texture Descriptor

Background: One of the challenges of PET/MRI combined systems is to derive an attenuation map to correct the PET image. For that, the pseudo-CT image could be used to correct the attenuation. Until now, most existing scientific researches construct this pseudo-CT image using the registration techniques. However, these techniques suffer from the local minima of the non-rigid deformation energy f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009