Postoperative macular hole formation after vitrectomy with internal limiting membrane peeling for the treatment of epiretinal membrane.

نویسندگان

  • Ryan B Rush
  • Matthew P Simunovic
  • Antonio V Aragon
  • Jason E Ysasaga
چکیده

PURPOSE To evaluate the incidence, clinical features, and outcomes of macular hole formation after pars plana vitrectomy with internal limiting membrane peeling for the management of epiretinal membrane. METHODS Retrospective consecutive chart review of 423 cases. RESULTS Eleven subjects developed postoperative macular holes (incidence 2.6%; 95% confidence interval, 1.5-4.6%). Two of the 11 subjects developed central macular holes (incidence 0.5%; 95% confidence interval, 0.1-1.7%) while 9 had eccentric (nonfoveal) macular holes (incidence 2.1%; 95% confidence interval, 1.1-4.0%). Seven of the 9 eccentric macular holes were <115 µm in diameter, 7 were determined to be along the margin of the internal limiting membrane peel, and 8 were either in the superior or temporal macula. The two central macular holes were closed with subsequent pars plana vitrectomy and gas tamponade. There was no association between macular hole formation and age, gender, preoperative visual acuity, axial length, and preoperative central macular thickness. Overall, a 0.2 or more improvement in logMAR was associated with pseudophakia and poorer preoperative acuity on univariate and multivariate analysis, whereas increased preoperative central macular thickness was associated with improved outcomes on univariate but not multivariate analysis. CONCLUSION Postoperative macular hole formation is an infrequent sequela to pars plana vitrectomy with internal limiting membrane peeling for epiretinal membrane. In our cohort, eccentric macular holes tended to be small, located along the edge of the internal limiting membrane peel, and were not visually significant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Eccentric Macular Hole after Pars Plana Vitrectomy for Epiretinal Membrane Without Internal Limiting Membrane Peeling: A Case Report

INTRODUCTION Postoperative eccentric macular hole formation is an uncommon complication after pars plana vitrectomy (PPV) without internal limiting membrane (ILM) peeling for the treatment of epiretinal membrane (ERM). We present a case of eccentric macular hole formation after PPV for ERM without ILM peeling. CASE REPORT A 68-year-old male patient presented with ERM and visual acuity of 6/24...

متن کامل

Eccentric Macular Hole after Pars Plana Vitrectomy for Idiopathic Macular Hole: A Case Report

INTRODUCTION Postoperative eccentric macular hole (MH) formation is an uncommon complication after pars plana vitrectomy (PPV) with internal limiting membrane (ILM) peeling for epiretinal membrane or MH treatment. Herein, we present a case of eccentric MH formation after PPV with ILM peeling for MH. CASE DESCRIPTION A 72-year-old female patient underwent 23-gauge PPV with ILM peeling for idio...

متن کامل

Three-Dimensional Analysis of Peeled Internal Limiting Membrane Using Focused Ion Beam/Scanning Electron Microscopy

Purpose To reevaluate the effect of internal limiting membrane peeling during vitrectomy on the Müller cell damage, we examined the ultrastructure of the internal limiting membrane by using focused ion beam/scanning electron microscopy (FIB/SEM). Methods A total of 12 internal limiting membranes obtained during surgery in both the macular hole and the idiopathic epiretinal membrane groups wer...

متن کامل

Role of Tractional Forces and Internal Limiting Membrane in Macular Hole Formation: Insights from Intraoperative Optical Coherence Tomography

We report the case of a 69-year-old patient who underwent vitrectomy for vitreomacular traction (VMT) and developed a postoperative macular hole that was observed 1 week after surgery. The hole did not close by in-office fluid-gas exchange alone, but was achieved after repeat surgery with internal limiting membrane (ILM) peeling. Intraoperative OCT (iOCT) images from the first surgery revealed ...

متن کامل

Successful Closure of Iatrogenic Double Macular Hole Using inverted Internal Limiting Membrane Flap Technique-Case Report

Purpose: To present a case study describing inverted internal limiting membrane flap technique used after failed treatment of double large fullthickness macular hole. Case presentation: A 79-year-old woman presented large full-thickness macular hole after primary failed pars plana vitrectomy with internal limiting membrane (ILM) peeling and SF6 gas endotamponade. The corrected distance visual a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Retina

دوره 34 5  شماره 

صفحات  -

تاریخ انتشار 2014