Two-dimensional aperture coding for magnetic sector mass spectrometry.

نویسندگان

  • Zachary E Russell
  • Evan X Chen
  • Jason J Amsden
  • Scott D Wolter
  • Ryan M Danell
  • Charles B Parker
  • Brian R Stoner
  • Michael E Gehm
  • David J Brady
  • Jeffrey T Glass
چکیده

In mass spectrometer design, there has been a historic belief that there exists a fundamental trade-off between instrument size, throughput, and resolution. When miniaturizing a traditional system, performance loss in either resolution or throughput would be expected. However, in optical spectroscopy, both one-dimensional (1D) and two-dimensional (2D) aperture coding have been used for many years to break a similar trade-off. To provide a viable path to miniaturization for harsh environment field applications, we are investigating similar concepts in sector mass spectrometry. Recently, we demonstrated the viability of 1D aperture coding and here we provide a first investigation of 2D coding. In coded optical spectroscopy, 2D coding is preferred because of increased measurement diversity for improved conditioning and robustness of the result. To investigate its viability in mass spectrometry, analytes of argon, acetone, and ethanol were detected using a custom 90-degree magnetic sector mass spectrometer incorporating 2D coded apertures. We developed a mathematical forward model and reconstruction algorithm to successfully reconstruct the mass spectra from the 2D spatially coded ion positions. This 2D coding enabled a 3.5× throughput increase with minimal decrease in resolution. Several challenges were overcome in the mass spectrometer design to enable this coding, including the need for large uniform ion flux, a wide gap magnetic sector that maintains field uniformity, and a high resolution 2D detection system for ion imaging. Furthermore, micro-fabricated 2D coded apertures incorporating support structures were developed to provide a viable design that allowed ion transmission through the open elements of the code.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Compatibility of Spatially Coded Apertures with a Miniature Mattauch-Herzog Mass Spectrograph.

In order to minimize losses in signal intensity often present in mass spectrometry miniaturization efforts, we recently applied the principles of spatially coded apertures to magnetic sector mass spectrometry, thereby achieving increases in signal intensity of greater than 10× with no loss in mass resolution Chen et al. (J. Am. Soc. Mass Spectrom. 26, 1633-1640, 2015), Russell et al. (J. Am. So...

متن کامل

Design and performance of a high resolution electrospray ion source for a magnetic sector mass spectrometer with a heated capillary inlet.

The design and performance of an electrospray ion source for a high resolution magnetic sector mass spectrometer that utilizes a heated capillary has been presented. Low pressure, high sensitivity, stable electrospray, low flow rates, and low electronic noise were important factors in achieving high resolution electrospray mass spectrometry. A unit mass resolution has been achieved for biomolec...

متن کامل

Carbon-13 labeling for quantitative analysis of molecular movement in heterogeneous organic materials using secondary ion mass spectrometry.

Secondary ion mass spectrometry (SIMS) is used to probe the movement of macromolecules in heterogeneous organic systems. Using 13C tracer labeling and two model systems, polystyrene/poly(2-vinylpyridine) (PS/P2VP) and polystyrene/poly(4-bromostyrene) (PS/P4BrS), the diffusion of 13C-labeled PS has been investigated near the respective heterogeneous interfaces using a CAMECA-IMS-6F magnetic sect...

متن کامل

Detection of femtomole and sub-femtomole levels of peptides by tandem magnetic sector/reflectron time-of-flight mass spectrometry and matrix-assisted laser desorption ionization.

This article describes results of low-level (sub-femtomole) detection of peptides by matrix-assisted laser desorption ionization. The matrix-assisted laser desorption ionization method can be used for low-level detection of the parent ion, either [M + H](+) or [M + Na](+), and collision-induced dissociation of the parent ion can be performed at the picomole level. The instrument used for these ...

متن کامل

Effects of variations in magnetic Reynolds number on magnetic field distribution in electrically conducting fluid under magnetohydrodynamic natural convection

In this study the effect of magnetic Reynolds number variation on magnetic distribution of natural convection heat transfer in an enclosure is numerically investigated. The geometry is a two dimensional enclosure which the left wall is hot, the right wall is cold and the top and bottom walls are adiabatic. Fluid is molten sodium with Pr=0.01 and natural convection heat transfer for Rayleigh num...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of the American Society for Mass Spectrometry

دوره 26 2  شماره 

صفحات  -

تاریخ انتشار 2015