Comparative cost and performance of light-emitting diode microscopy in HIV-tuberculosis-co-infected patients.

نویسندگان

  • A Whitelaw
  • J Peter
  • H Sohn
  • D Viljoen
  • G Theron
  • M Badri
  • V Davids
  • M Pai
  • K Dheda
چکیده

Light-emitting diode (LED) microscopy has recently been endorsed by the World Health Organization (WHO). However, it is unclear whether LED is as accurate and cost-effective as Ziehl-Neelsen (ZN) microscopy or mercury vapour fluorescence microscopy (MVFM) in tuberculosis (TB)-HIV-co-infected subjects. Direct and concentrated sputum smears from TB suspects were evaluated using combinations of LED microscopy, ZN microscopy and MVFM. Median reading time per slide was recorded and a cost analysis performed. Mycobacterial culture served as the reference standard. 647 sputum samples were obtained from 354 patients (88 (29.8%) were HIV-infected and 161 (26%) were culture-positive for Mycobacterium tuberculosis). Although overall sensitivity of LED compared with ZN microscopy or MVFM was similar, sensitivity of all three modalities was lower in HIV-infected patients. In the HIV-infected group, the sensitivity of LED microscopy was higher than ZN microscopy using samples that were not concentrated (46 versus 39%; p = 0.25), and better than MVFM using concentrated samples (56 versus 44; p = 0.5). A similar trend was seen in the CD4 count <200 cells · mL(-1) subgroup. Median (interquartile range) reading time was quicker with LED compared with ZN microscopy (1.8 (1.7-1.9) versus 2.5 (2.2-2.7) min; p ≤ 0.001). Average cost per slide read was less for LED microscopy (US$1.63) compared with ZN microscopy (US$2.10). Among HIV-TB-co-infected patients, LED microscopy was cheaper and performed as well as ZN microscopy or MVFM independent of the staining (ZN or auramine O) or processing methods used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid Diagnosis of Pulmonary and Extrapulmonary Tuberculosis in HIV-Infected Patients. Comparison of LED Fluorescent Microscopy and the GeneXpert MTB/RIF Assay in a District Hospital in India

HIV-related tuberculosis is difficult to diagnose and is associated with high morbidity and mortality. Recently, the World Health Organization has endorsed the GeneXpert MTB/RIF (Xpert) assay for the diagnosis of pulmonary tuberculosis in HIV-infected patients from developing countries, but information about the use of Xpert for the diagnosis of extrapulmonary tuberculosis is scarce. In this st...

متن کامل

[Performance of LED fluorescence microscopy for the detection of acid-fast bacilli from respiratory samples in peripheral laboratories in Argentina].

INTRODUCTION Light-emitting diode fluorescence microscopy (LED-FM) has been endorsed by the World Health Organization (WHO) for tuberculosis diagnosis, but its accuracy in HIV-infected patients remains controversial, and only some few studies have explored procedural factors that may affect its performance. OBJECTIVE To evaluate the performance of LED-FM for tuberculosis diagnosis in patients...

متن کامل

Light-emitting diode fluorescence microscopy for tuberculosis diagnosis: a meta-analysis.

Light-emitting diode fluorescence microscopy (LED-FM) is recommended by the World Health Organization to replace conventional Ziehl-Neelsen microscopy for pulmonary tuberculosis diagnosis. Uptake of LED-FM has been slow. One reason is its reported loss of specificity compared with Ziehl-Neelsen microscopy. We aimed to determine the diagnostic accuracy of LED-FM for tuberculosis detection and ex...

متن کامل

Operational Implementation of LED Fluorescence Microscopy in Screening Tuberculosis Suspects in an Urban HIV Clinic in Uganda

BACKGROUND Light emitting diode (LED) fluorescence microscopy (FM) is an affordable, technology targeted for use in resource-limited settings and recommended for widespread roll-out by the World Health Organization (WHO). We sought to compare the operational performance of three LED FM methods compared to light microscopy in a cohort of HIV-positive tuberculosis (TB) suspects at an urban clinic...

متن کامل

Performance of Three LED-Based Fluorescence Microscopy Systems for Detection of Tuberculosis in Uganda

BACKGROUND Direct smear microscopy using Ziehl-Neelsen (ZN) staining is the mainstay of tuberculosis (TB) diagnosis in most high burden countries, but is limited by low sensitivity in routine practice, particularly in high human immunodeficiency virus (HIV) prevalence settings. METHODS We compared the performance of three commercial light emitting diode (LED)-based microscopy systems (Primost...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 38 6  شماره 

صفحات  -

تاریخ انتشار 2011