Peri-implant bone remodeling after total hip replacement combined with systemic alendronate treatment: a finite element analysis.
نویسندگان
چکیده
In order to decrease the peri-implant bone loss during the life-time of the implant, oral use of anti-osteoporosis drugs (like bisphosphonates) has been suggested. In this study, bone remodeling parameters identified from clinical trials of alendronate were used to simulate the effect of those drugs used after total hip arthroplasty on the peri-implant bone density. Results of the simulation show that the oral administrated drugs increase bone density around the implant and decreases, at the same time, the micromovements between the implant and the surrounding bone tissue. Incorporation of drug effect in numerical studies of bone remodeling is a promising tool especially to predetermine safe bisphosphonate doses that could be used with orthopedic implants.
منابع مشابه
تعیین توزیع تنش استخوان اطراف ایمپلنتهای فک پایین در طرحهای مختلف پروتز به هنگام Mandibular- Flexure
Statement of Problem: In the treatment of edentulous patients with implant supported fixed partial dentures several factors such as implant numbers, implant position, superstructure pattern and cantilever length must be considered. Mandibular flexture in function exerts forces in peri-implant bone, however this phenomenon has received little attention. Purpose: The goal of this finite element a...
متن کامل0526 - the Effect of Alendronate and Implant Surface on Bone Growth and Remodeling in a Canine Implantable Chamber
Introduction The aim of this study was to determine the effect of short-term treatment with alendronate (FosamaxTM) on bone proliferation and attachment using three metal surfaces in normal canines and ovariectomized (OVX) canines fed a low-calcium diet. Alendronate (ALN) suppresses osteoclast number and function and decreases remodeling rate of cancellous bone. It may slow periprosthetic bone ...
متن کاملEffect of Coating Materials on the Fatigue Behavior of Hip Implants: A Three-dimensional Finite Element Analysis
This study aims to validate, using finite element analysis (FEA), the design concept by comparing the fatigue behavior of hip implant stems coated with composite (carbon/PEEK) and polymeric (PEEK) coating materials corresponding to different human activities: standing up, normal walking and climbing stairs under dynamic loadings to find out which of all these models have a better performance in...
متن کاملCorrelation between Periacetabular Bone Density Changes and Stress Behaviour after Total Hip Arthroplasty
Introduction Little is know about periacetabular bone remodeling after insertion of the acetabular cup in total hip Arthroplasty. Dual energy X-ray absorptiometry (DXA) is commonly used for quantitative assessment of bone remodeling after total hip arthroplasty (THA). DXA is limited by low resolution and a lack of three-dimensional information. Computed tomography (CT) is a standardized radiolo...
متن کاملOrthopedic Implants Used as Drug Delivery Systems: Numerical, in Vitro and in Vivo Studies
Total Hip Replacement (THR) is today a routine procedure executed more than 800’000 times per year worldwide. THR gives generally satisfactory results, although the quality of outcome is inversely proportional to the age of the patient. In parallel, there is a trend to propose cementless THR to patients younger than 60 years. These patients have more demanding physical activity resulting in a s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Computer methods in biomechanics and biomedical engineering
دوره 7 2 شماره
صفحات -
تاریخ انتشار 2004