Z-scan measurement technique for non-Gaussian beams and arbitrary sample thicknesses.

نویسندگان

  • R E Bridges
  • G L Fischer
  • R W Boyd
چکیده

We demonstrate a new Z-scan measurement technique that permits the use of non-Gaussian beams and thick, as well as thin, samples. We expect that this technique will make possible the measurement of optical nonlinearities by the use of lasers that previously would have been unsuitable for this purpose, because of either inadequate beam quality or inadequate power. Another advantage of this technique is that it does not require detailed knowledge of the temporal characteristics of the laser pulse that is used.  1995 Optical Society of America

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

اندازه‌گیری ضریب شکست غیر خطی در شیشه‌های آلاییده به بلورهای نیمرسانا

  There are several techniques in use for non-linear refractive index measurement, namely, interferometric techniques, in which conventional inter-ferometers are used, degenerate for wave mixing (DFWM), and z-scan, Each of these techniques suffers from some shortcmings. For example conventional interferometers like Fabry-Perot and Twyman-Green need high quality optical components, unwanted refl...

متن کامل

Optimization of Gate’s technique for measurement of GFR during routine renal scan [Persian]

Using Gate’s technique for GFR measurement with Gamma camera, the patient is received 5mCi of Tc-99m-DTPA. By this amount of radioactivity, good quality renal scan is not possible. This study tries to optimize Gate’s technique for GFR measurement during routine renal scan (with 10-15 mCi). Methods and materials: Scanning was performed for 60 seconds from samples of Tc-99m with activities ...

متن کامل

Z-scan experiment with anisotropic Gaussian Schell-model beams.

We analyze the z-scan experiment with anisotropic Gaussian Schell-model (AGSM) beams. The expression for the cross-spectral density of the AGSM beam passing through the lens and onto the nonlinear thin sample is derived. Based on the expression, we simulate the results of the z-scan experiment theoretically and analyze the effects of the e factor (e=w(0x)/w(0y)) and the spatial degree of cohere...

متن کامل

Study of nonlinear optical properties of Carbon nanotubes synthesized by Nickel and Nickel-Cobalt catalysts using Z-scan technique

The nonlinear optical properties of carbon nanotubes (CNTs) have been studied by using the Z-scan technique. Experiments are performed by CW second harmonic of Nd-YAG laser at 532 nm wavelength with a power of 40 mW. The samples are synthesized by the chemical vapor deposition (CVD) method in the presence of Nickel and Nickel-Cobalt catalysts. In this work, for the first time, effect of the typ...

متن کامل

Robust Distributed Source Coding with Arbitrary Number of Encoders and Practical Code Design Technique

The robustness property can be added to DSC system at the expense of reducing performance, i.e., increasing the sum-rate. The aim of designing robust DSC schemes is to trade off between system robustness and compression efficiency. In this paper, after deriving an inner bound on the rate–distortion region for the quadratic Gaussian MDC based RDSC system with two encoders, the structure of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics letters

دوره 20 17  شماره 

صفحات  -

تاریخ انتشار 1995