Evaluation of an enzymatic Chlamydia trachomatis point-of-care rapid assay in Rwanda: the BioChekSwab Rapid Test.

نویسندگان

  • Irith De Baetselier
  • Lambert Mwambarangwe
  • Vicky Cuylaerts
  • Viateur Musengamana
  • Stephen Agaba
  • Evelyne Kestelyn
  • Janneke van de Wijgert
  • Tania Crucitti
چکیده

OBJECTIVES We evaluated the performance of an enzymatic point-of-care rapid test for Chlamydia trachomatis (CT) (the BioChekSwab CT Rapid Test, EnZtek Diagnostics, Rio Vista, California, USA), which detects CT's Peptidase 123CBV enzyme and provides a result 15 min after specimen collection. METHODS Two endocervical swabs, including one BioChekSwab, per person were obtained from 137 women who participated in a reproductive health study in Rwanda. The BioChekSwab was processed according to the manufacturer's instructions. A substrate was squirted over the swab by the study physician immediately after collection, and another reagent was released over the swab tip at arrival in the laboratory. The test was considered positive if a blue colour developed within 2 min. The other regular flocked endocervical swab was processed at the Institute of Tropical Medicine (ITM), Belgium, using a testing algorithm: Abbott RealTime CT/Neisseria gonorrhoeae (NG) assay with the confirmation of positive results by an in-house real-time PCR assay. RESULTS Of the 137 women, nine were CT positive by the testing algorithm. All nine positive results were missed by the BioChekSwab assay and four false-positive results were obtained. The sensitivity was therefore 0% (95% CI 0% to 33.6%) and the specificity was 96.9% (95% CI 92.2% to 99.1%). CONCLUSIONS The BioChekSwab Rapid Test, although ISO13485 certified and Conformitée Européenne (CE) labelled, lacked any sensitivity in our setting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New point of care Chlamydia Rapid Test--bridging the gap between diagnosis and treatment: performance evaluation study.

OBJECTIVE To evaluate the performance of a new Chlamydia Rapid Test with vaginal swab specimens as a potential tool for chlamydia diagnosis and screening. DESIGN Performance evaluation study. Settings A young people's sexual health centre (site 1) and two genitourinary medicine clinics (sites 2 and 3) in the United Kingdom. PARTICIPANTS 1349 women aged between 16 and 54 attending one of the...

متن کامل

Decision analysis: point-of-care Chlamydia testing vs. laboratory-based methods.

OBJECTIVE To evaluate and compare the performance of several different methods available for detection of Chlamydia trachomatis (Ct) infection, and to explore possible testing and treatment strategies incorporating point-of-care testing versus laboratory-based tests. DESIGN Prospective trial and decision analysis. SETTING Large, urban, publicly funded sexually transmitted disease clinic. ...

متن کامل

بررسی مقایسه‌ای روشهای میکروایمونوفلئورسانس، الیزا، کیت تشخیص سریع Dima و رنگ‌آمیزی گیمنز در تشخیص سرویسیت کلامیدیایی

    Background & Aim: Chlamydia trachomatis is one of the most prevalent causative agents of sexually transmitted diseases. It causes a variety of genital tract complications such as urethritis, cervicitis, endometritis, epididymitis and lymphogranuloma venereum. The prevalence rate of chlamydia induced cervicitis varies in different societies. In a recent study, the prevalnce of chlamydia cerv...

متن کامل

Evaluation of Cortez OneStep Chlamydia Rapicard™ Insta Test for the Detection of Chlamydia trachomatis in Pregnant Women at Mbare Polyclinic in Harare, Zimbabwe

BACKGROUND Cervical chlamydia infection poses high risk of pregnancy complications and neonatal infection. Reference methods for the detection of chlamydia infection are not available for routine use in developing countries. Point-of-care (POC) tests can bridge this gap. This study evaluated Cortez Onestep Chlamydia Rapicard™ insta test for the detection of Chlamydia trachomatis in pregnant wom...

متن کامل

Blind evaluation of the microwave-accelerated metal-enhanced fluorescence ultrarapid and sensitive Chlamydia trachomatis test by use of clinical samples.

Accurate point-of-care (POC) diagnostic tests for Chlamydia trachomatis infection are urgently needed for the rapid treatment of patients. In a blind comparative study, we evaluated microwave-accelerated metal-enhanced fluorescence (MAMEF) assays for ultrafast and sensitive detection of C. trachomatis DNA from vaginal swabs. The results of two distinct MAMEF assays were compared to those of nuc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Sexually transmitted infections

دوره 92 6  شماره 

صفحات  -

تاریخ انتشار 2016