Transpulmonary thermodilution (TPTD) before, during and after Sustained Low Efficiency Dialysis (SLED). A Prospective Study on Feasibility of TPTD and Prediction of Successful Fluid Removal.
نویسندگان
چکیده
BACKGROUND Acute kidney injury (AKI) is common in critically ill patients. AKI requires renal replacement therapy (RRT) in up to 10% of patients. Particularly during connection and fluid removal, RRT frequently impairs haemodyamics which impedes recovery from AKI. Therefore, "acute" connection with prefilled tubing and prolonged periods of RRT including sustained low efficiency dialysis (SLED) has been suggested. Furthermore, advanced haemodynamic monitoring using trans-pulmonary thermodilution (TPTD) and pulse contour analysis (PCA) might help to define appropriate fluid removal goals. OBJECTIVES, METHODS Since data on TPTD to guide RRT are scarce, we investigated the capabilities of TPTD- and PCA-derived parameters to predict feasibility of fluid removal in 51 SLED-sessions (Genius; Fresenius, Germany; blood-flow 150 mL/min) in 32 patients with PiCCO-monitoring (Pulsion Medical Systems, Germany). Furthermore, we sought to validate the reliability of TPTD during RRT and investigated the impact of "acute" connection and of disconnection with re-transfusion on haemodynamics. TPTDs were performed immediately before and after connection as well as disconnection. RESULTS Comparison of cardiac index derived from TPTD (CItd) and PCA (CIpc) before, during and after RRT did not give hints for confounding of TPTD by ongoing RRT. Connection to RRT did not result in relevant changes in haemodynamic parameters including CItd. However, disconnection with re-transfusion of the tubing volume resulted in significant increases in CItd, CIpc, CVP, global end-diastolic volume index GEDVI and cardiac power index CPI. Feasibility of the pre-defined ultrafiltration goal without increasing catecholamines by >10% (primary endpoint) was significantly predicted by baseline CPI (ROC-AUC 0.712; p = 0.010) and CItd (ROC-AUC 0.662; p = 0.049). CONCLUSIONS TPTD is feasible during SLED. "Acute" connection does not substantially impair haemodynamics. Disconnection with re-transfusion increases preload, CI and CPI. The extent of these changes might be used as a "post-RRT volume change" to guide fluid removal during subsequent RRTs. CPI is the most useful marker to guide fluid removal by SLED.
منابع مشابه
Renal replacement therapy with net fluid removal lowers intra-abdominal pressure and volumetric indices in critically ill patients
BACKGROUND Little is known about the effects of renal replacement therapy (RRT) with fluid removal on intra-abdominal pressure (IAP). The global end-diastolic volume index (GEDVI) and extravascular lung water index (EVLWI) can easily be measured bedside by transpulmonary thermodilution (TPTD). The aim of this study is to evaluate the changes in IAP, GEDVI and EVLWI in critically ill patients re...
متن کاملA protocol for resuscitation of severe burn patients guided by transpulmonary thermodilution and lactate levels: a 3-year prospective cohort study
INTRODUCTION The use of urinary output and vital signs to guide initial burn resuscitation may lead to suboptimal resuscitation. Invasive hemodynamic monitoring may result in over-resuscitation. This study aimed to evaluate the results of a goal-directed burn resuscitation protocol that used standard measures of mean arterial pressure (MAP) and urine output, plus transpulmonary thermodilution (...
متن کاملTranspulmonary thermodilution using femoral indicator injection: a prospective trial in patients with a femoral and a jugular central venous catheter
INTRODUCTION Advanced hemodynamic monitoring using transpulmonary thermodilution (TPTD) is established for measurement of cardiac index (CI), global end-diastolic volume index (GEDVI) and extra-vascular lung water index (EVLWI). TPTD requires indicator injection via a central venous catheter (usually placed via the jugular or subclavian vein). However, superior vena cava access is often not fea...
متن کاملAssessment of cardiac output with transpulmonary thermodilution during exercise in humans.
The accuracy and reproducibility of transpulmonary thermodilution (TPTd) to assess cardiac output (Q̇) in exercising men was determined using indocyanine green (ICG) dilution as a reference method. TPTd has been utilized for the assessment of Q̇ and preload indexes of global end-diastolic volume and intrathoracic blood volume, as well as extravascular lung water (EVLW) in resting humans. It remai...
متن کاملMain limitations of transpulmonary thermodilution: set targets
Background We read with great interest the review by Xavier Monnet and Jean-Louis Teboul [1]. This review concluded that transpulmonary thermodilution (TPTD) provides a full haemodynamic evaluation. The authors discuss the limitations of previous studies reporting a lack of outcome improvement in patients treated using TPTD-based fluid management. They stated that the objectives of these studie...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- PloS one
دوره 11 4 شماره
صفحات -