Effect of partial-filling autotransfusion bowls on the quality of reinfused product.
نویسندگان
چکیده
Intraoperative autotransfusion is used in a variety of surgical procedures with the quantity of blood loss dependent upon numerous factors. These procedures may or may not produce a full autotransfusion bowl. The inadequate removal of contaminants has been correlated to the incomplete filling of bowls, resulting in a condition called "Salvaged Blood Syndrome." The purpose of this study was to assess the quality of aspirated whole blood after processing with an autotransfusion system using various fill volumes and two wash volumes. An in vitro circuit was designed to mimic the mechanical effects of extracorporeal flow on blood. Twenty-four Baylor-style bowls were filled at 400 mL min(-1) and washed at 300 mL min(-1). Two wash volumes, 1000 and 2000 mL, and three bowl volumes: low, mid, and full, were used in this study. The bowl volumes were determined by using red cell quantities of 60, 100, and 135 mL for the low-fill, mid-fill, and full bowls, respectively. Samples were drawn pre-autotransfusion and post-autotransfusion and analyzed for plasma-free hemoglobin, IL-8, white blood cell count, platelet count, albumin, and total protein. All data were analyzed using one-way analysis of variance (ANOVA) with significance accepted at p > or = .05. Plasma-free hemoglobin levels and hematocrit were concentrated significantly (p < .05) as bowl volume increased. A significant difference in IL-8 levels was found in the wash volumes in the low-fill bowls (p < .02). Platelet count was significantly decreased between the full bowl with 1000 mL wash and the full bowl with 2000 mL wash (p < .0004). Total protein reduction was significantly less in the low-fill bowl with 1000 mL wash as compared to the other bowl treatments (p < .05). In conclusion, the quality of the washed product did not vary significantly between fill or wash volumes, with the exception of the low-fill bowl with 1000 mL wash.
منابع مشابه
The impact of bowl size, program setup, and blood hematocrit on the performance of a discontinuous autotransfusion system.
BACKGROUND Cell salvage is an essential element in the concept of blood management. Modern devices provide different bowl sizes and sensor-directed programs to optimally adjust to varying clinical situations. STUDY DESIGN AND METHODS In an experimental performance study, the discontinuous autotransfusion device XTRA (LivaNova/Sorin) was evaluated using fresh donor blood anticoagulated with he...
متن کاملEffect of Planting Pattern and Irrigation Method on Germination of Mung Bean (Vigna radiate) Harvested at Different Times of Maturation
DOR: 98.1000/2383-1251.1398.6.51.11.1. 1575.1578 Extended Abstract Introduction: Pulses are a group of crops which are important in human nutrition and also sustainability of agronomical systems and economic advantage. Regarding optimum planting density of mung beans (40 plant m-2), more than 700 tons of certified seeds of mung bean seeds are needed all over the country, confirming the im...
متن کاملPartial bowls using the Haemonetics Cell Saver 5: does it produce a quality product?
Controversy still exists on the validity of processing a partial bowl during the collection of shed blood lost through surgery during cell salvaging. The purpose of this study was to assess the quality of red blood cells produced from a partial bowl of autologous suctioned blood using the Haemonetics Cell Saver 5. Suctioned blood was collected from 17 patients undergoing cardiac surgery. A part...
متن کاملEvaluating the Effect of Dental Filling Material and Filling Depth on the Strength and Deformation of Filled Teeth
ackground and aim: It is important to evaluate the effect of the type of filling material on deformation and strength of tooth after filling and also the effect of filling depth on quality of restoration of a decayed tooth. Material and Methods: The Orthopantomogram (OPG) of the first and second molars of a 28-year-old man was made and the teeth were 3D modeled. The stress-deformation analysis ...
متن کاملDebris elimination from partially-filled cell salvage bowls.
Centrifuge-based cell salvage and washing systems, available since the 1970s, have decreased the use of allogeneic blood transfusions (1). Although intraoperative salvage and autotransfusion avoids the risks of allogeneic transfusion, case reports document adverse reactions to this blood, potentially related to inadequate washing (2). The cleanliness of partially filled cell salvage bowls has b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The journal of extra-corporeal technology
دوره 33 2 شماره
صفحات -
تاریخ انتشار 2001