Measurements of the capacitance and the response time of solid-state potentiometric sensors by an electrochemical time-of-flight method

نویسندگان

  • Katarzyna Slowinska
  • Marcin Majda
چکیده

A micro-electrochemical time-of-flight technique relying on galvanostatic ion generation and potentiometric sensing (P-ETOF) has been developed in order to characterize dynamic properties of solid-state potentiometric sensors and to measure their capacitance. Lithographically-fabricated generator-sensor devices featuring 10 lm-wide micro-electrodes spaced by 20– 50 lm are used in either an open face mode, where hemicylindrical diffusion governs mass transport of generated ions, or in a narrow channel mode, where linear diffusion describes transport of ions between the generator and sensor micro-electrodes in a thin ( 3 lm) layer of electrolyte. P-ETOF-open face mode is capable of generating silver ions or protons at a rate equivalent to a current density of 10 A/cm. This induces a maximum, mass transport controlled rate of a sensor potential rise of 80 V/s. P-ETOF was used to characterize anodically electrodeposited iridium oxide film pH micro-sensors. Their maximum rate of potential change was determined to depend inversely on the oxide film’s thickness and varied from 34 V/s for 40 nm-thick films to 9 V/s for the 650 nm-thick iridium oxide films. The capacitances of these pH micro-sensors were determined to depend linearly on their thicknesses, with a slope of 3 lF cm nm and a specific capacitance of 30 F/cm. These results point to slow proton transport in the bulk of the oxide film as a mechanistic element of their pH response.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of the capacitance of solid-state potentiometric sensors: An electrochemical time-of-flight method.

A dual microelectrode electrochemical time-of-flight technique in which diffusion flux of Ag+, Cl-, or H+ ions electrochemically produced at a generator electrode is measured by recording potential-time transients with Ag, Ag/AgCl, or iridium oxide potentiometric microsensors, respectively, is developed. The generator and microsensor electrodes are typically spaced by 50-100 microm and are inco...

متن کامل

Green Potentiometric Method for Determination of Triprolidine Hydrochloride and Pseudoephedrine Hydrochloride in their Different Pharmaceutical Matrices using Liquid and Solid Contact Gold Electrodes

Factors affecting the performance of polyvinyl chloride based ion selective electrode such as using different cationic exchangers and ionophores as well as sensor fabrication procedures were recently the scope of study by several researchers. This work presents an environment friendly electro-analytical method for the determination of Triprolidine HCl (TRI) and Pseudoephedrine HCl (PSE). A comp...

متن کامل

All-solid-state potassium-selective electrode using graphene as the solid contact.

Graphene sheets are used for the first time to fabricate a new type of solid-contact ion-selective electrode (SC-ISE) as the intermediate layer between an ionophore-doped solvent polymeric membrane and a glassy carbon electrode. The new transducing layer was characterized by transmission electron microscopy, scanning electron microscopy, cyclic voltammetry and electrochemical impedance spectros...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

Development of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples

This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004