Comparison of three ways to determine and deliver pressure during nasal CPAP therapy for obstructive sleep apnoea.

نویسندگان

  • S D West
  • D R Jones
  • J R Stradling
چکیده

BACKGROUND The simplest method of initiating and maintaining therapeutic continuous positive airways pressure (CPAP) therapy for obstructive sleep apnoea (OSA) has not been established. METHODS Ninety eight subjects with OSA requiring CPAP treatment (more than 10 dips in oxygen desaturation of >4% per hour of sleep study and Epworth Sleepiness Score (ESS) >9) were randomised prospectively to three different methods of CPAP delivery for 6 months: (1) autotitration pressure throughout; (2) autotitration pressure for 1 week followed by fixed pressure (95th centile) thereafter; and (3) fixed pressure determined by algorithm (based on neck size and dip rate). Patients and investigators were blind to group allocation. One week after initiation the patients were routinely reviewed by sleep nurses. Study assessments took place before starting CPAP treatment and 1 and 6 months after to assess ESS, maintenance of wakefulness test, 24 hour blood pressure, general health (SF-36), and sleep apnoea related quality of life. CPAP internal monitoring data were also collected. RESULTS There were no significant differences in any of the outcome measures or CPAP monitoring data between the three groups. The 95th centile CPAP pressures delivered in the 6 month and 1 week autotitration groups were higher than in the algorithm group, but the median pressures were lowest in the 6 month autotitration group. CONCLUSIONS The method of determining CPAP pressure for treatment of moderate to severe OSA makes no significant difference to clinical outcome measures. The autotitration CPAP machine used has no advantage in this setting over simpler methods of pressure determination.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SLEEP DISORDERED BREATHING Comparison of three ways to determine and deliver pressure during nasal CPAP therapy for obstructive sleep apnoea

Background: The simplest method of initiating and maintaining therapeutic continuous positive airways pressure (CPAP) therapy for obstructive sleep apnoea (OSA) has not been established. Methods: Ninety eight subjects with OSA requiring CPAP treatment (more than 10 dips in oxygen desaturation of .4% per hour of sleep study and Epworth Sleepiness Score (ESS) .9) were randomised prospectively to ...

متن کامل

Factors Affecting Patients’ Adherence to Continuous Positive Airway Pressure Therapy for Obstructive Sleep Apnea Disorder: A Multi-Method Approach

Background: Continuous positive airway pressure (CPAP) is the gold standard therapy for treating obstructive sleep apnea (OSA) disorder. However, patients’ adherence to its regular use is poor. The present study aimed to determine the adherence rate to CPAP therapy by identifying factors affecting its regular use and its associated problems and discomforts among a sample population in Mashhad (...

متن کامل

Effect of nasal CPAP on ventilatory drive in normocapnic and hypercapnic patients with obstructive sleep apnoea syndrome.

The purpose of this study was to evaluate the effect of nasal continuous positive airway pressure (CPAP) on the abnormal ventilatory drive in hypercapnic patients with the obstructive sleep apnoea syndrome (OSAS). Six patients with hypercapnic OSAS (Group I) and 24 patients with eucapnic OSAS (Group II) were studied. All patients had arterial blood gas analysis, overnight sleep studies, and an ...

متن کامل

Objective measurement of compliance with nasal CPAP treatment for obstructive sleep apnoea syndrome.

Compliance with nasal continuous positive airway pressure (CPAP) has become a major concern, since this treatment is efficacious, but constraining. In 46 consecutive obstructive sleep apnoea (OSA) patients, we measured compliance with nasal CPAP by establishing a mean rate of use, with a built-in time counter read at three-month intervals, over a mean follow-up period of 232 +/- 27 days. The me...

متن کامل

Nasal CPAP and weight loss in hypertensive patients with obstructive sleep apnoea.

BACKGROUND The high prevalence of obstructive sleep apnoea (OSA) in patients with systemic hypertension and of hypertension in patients with OSA suggests a causal link between the two disorders. This study was carried out to determine whether nasal continuous positive airway pressure (CPAP) and weight loss affect daytime hypertension in OSA. METHODS Sixty hypertensive patients with OSA took p...

متن کامل