Survey of total error of precipitation and homogeneous HDL-cholesterol methods and simultaneous evaluation of lyophilized saccharose-containing candidate reference materials for HDL-cholesterol.

نویسندگان

  • C Cobbaert
  • P G Mulder
  • H Baadenhuijsen
  • L Zwang
  • C W Weykamp
  • P N Demacker
چکیده

BACKGROUND Standardization of HDL-cholesterol is needed for risk assessment. We assessed for the first time the accuracy of HDL-cholesterol testing in The Netherlands and evaluated 11 candidate reference materials (CRMs). METHODS The total error (TE) of HDL-cholesterol measurements was assessed in native human sera by 25 Dutch clinical chemistry laboratories. Concomitantly, the suitability of lyophilized, saccharose-containing CRMs (n = 11) for HDL-cholesterol was evaluated. RESULTS In the precipitation method group, which included 25 laboratories and four methods, the mean (minimum-maximum) TE was 11.5% (2.7-25.2%), signifying that 18 of 25 laboratories satisfied the TE goal of </=13% issued by the National Cholesterol Education Program (NCEP). In the homogeneous HDL-cholesterol method group, which included five laboratories, each performing two different methods, the mean (minimum-maximum) TE was 9.5% (6.0-17.3%) for the Boehringer assay and 15.7% (3.3-30.7%) for the Genzyme assay. For the Boehringer homogeneous assay, one of five laboratories did not meet the TE criterion, whereas for the Genzyme homogeneous assay, three of five laboratories exceeded the 13% criterion. The biases on the HDL-cholesterol values found by various precipitation methods were highly variable in all CRMs, irrespective of the quality, whereas the biases found by the homogeneous method from Boehringer were far less than +/-5% for the highest-quality CRMs (CRMs 4-6). CONCLUSIONS The NCEP goal was met by 24 of 35 laboratories assessed by use of native human sera. Selectively pooled, lyophilized CRMs that are cryoprotected with 200 g/L saccharose have ample potential for use in the standardization of homogeneous HDL-cholesterol methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of quality-control materials for high-density-lipoprotein cholesterol quantitation.

Commercial quality-control materials and frozen plasma and serum pools were evaluated for high-density lipoprotein (HDL) cholesterol quantitation by the heparin-Mn2+ and phosphotungstate-Mg2+ precipitation methods and by ultracentrifugal and electrophoretic methods. We evaluated among-day precision; inter-method differences in HDL cholesterol quantitation; lipid composition and electrophoretic ...

متن کامل

Evolution of methods for measurement of HDL-cholesterol: from ultracentrifugation to homogeneous assays.

BACKGROUND Adoption of automated homogeneous assays for HDL-cholesterol (HDL-C) is increasing, driven by the need of clinical laboratories to cope with increasing workloads while containing costs. However, performance characteristics of homogeneous assays often differ in important aspects from those of the earlier precipitation methods. This review provides an overview of the new generation of ...

متن کامل

Comparison of a homogeneous assay with a precipitation method for the measurement of HDL cholesterol in diabetic patients.

OBJECTIVE To compare direct-measured HDL cholesterol with HDL cholesterol measured by a precipitation method. RESEARCH DESIGN AND METHODS We compared a homogeneous assay for direct HDL cholesterol analysis with the phosphotungstic acid magnesium chloride precipitation method in 55 type 1 diabetic patients, 70 type 2 diabetic patients, and 82 nondiabetic normal control subjects with plasma tri...

متن کامل

Reference standardization and triglyceride interference of a new homogeneous HDL-cholesterol assay compared with a former chemical precipitation assay.

A homogeneous HDL-c assay (HDL-H), which uses polyethylene glycol-modified enzymes and sulfated alpha-cyclodextrin, was assessed for precision, accuracy, and cholesterol and triglyceride interference. In addition, its analytical performance was compared with that of a phosphotungstic acid (PTA)/MgCl2 precipitation method (HDL-P). Within-run CVs were < or = 1.87%; total CVs were < or = 3.08%. Ac...

متن کامل

Selection, validation, standardization, and performance of a designated comparison method for HDL-cholesterol for use in the cholesterol reference method laboratory network.

BACKGROUND Accurate and precise HDL-cholesterol (HDL-C) measurements are essential for effective application of National Cholesterol Education Program treatment guidelines. The Cholesterol Reference Method Laboratory Network (CRMLN) assists manufacturers of in vitro diagnostic products to establish traceability to the accuracy base. CRMLN sought to implement a designated comparison method (DCM)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 45 3  شماره 

صفحات  -

تاریخ انتشار 1999