Non-invasive computer-assisted measurement of knee alignment.
نویسندگان
چکیده
The quantification of knee alignment is a routine part of orthopaedic practice and is important for monitoring disease progression, planning interventional strategies, and follow-up of patients. Currently available technologies such as radiographic measurements have a number of drawbacks. The aim of this study was to validate a potentially improved technique for measuring knee alignment under different conditions. An image-free navigation system was adapted for non-invasive use through the development of external infrared tracker mountings. Stability was assessed by comparing the variance (F-test) of repeated mechanical femoro-tibial (MFT) angle measurements for a volunteer and a leg model. MFT angles were then measured supine, standing and with varus-valgus stress in asymptomatic volunteers who each underwent two separate registrations and repeated measurements for each condition. The mean difference and 95% limits of agreement were used to assess intra-registration and inter-registration repeatability. For multiple registrations the range of measurements for the external mountings was 1° larger than for the rigid model with statistically similar variance (p=0.34). Thirty volunteers were assessed (19 males, 11 females) with a mean age of 41 years (range: 20-65) and a mean BMI of 26 (range: 19-34). For intra-registration repeatability, consecutive coronal alignment readings agreed to almost ±1°, with up to ±0.5° loss of repeatability for coronal alignment measured before and after stress maneuvers, and a ±0.2° loss following stance trials. Sagittal alignment measurements were less repeatable overall by an approximate factor of two. Inter-registration agreement limits for coronal and sagittal supine MFT angles were ±1.6° and ±2.3°, respectively. Varus and valgus stress measurements agreed to within ±1.3° and ±1.1°, respectively. Agreement limits for standing MFT angles were ±2.9° (coronal) and ±5.0° (sagittal), which may have reflected a variation in stance between measurements. The system provided repeatable, real-time measurements of coronal and sagittal knee alignment under a number of dynamic, real-time conditions, offering a potential alternative to radiographs.
منابع مشابه
Limb alignment in computer-assisted minimally-invasive unicompartmental knee replacement.
Twenty patients underwent simultaneous bilateral medial unicompartmental knee arthroplasty. Pre-operative hip-knee-ankle alignment and valgus stress radiographs were used to plan the desired post-operative alignment of the limb in accordance with established principles for unicompartmental arthroplasty. In each patient the planned alignment was the same for both knees. Overall, the mean planned...
متن کاملAre systemic emboli reduced in computer-assisted knee surgery?: A prospective, randomised, clinical trial.
We undertook a prospective, randomised study using a non-invasive transcranial Doppler device to evaluate cranial embolisation in computer-assisted navigated total knee arthroplasty (n = 14) and compared this with a standard conventional surgical technique using intramedullary alignment guides (n = 10). All patients were selected randomly without the knowledge of the patient, anaesthetists (bef...
متن کاملNavigated shorter incision or smaller implant in knee arthritis?
Minimally invasive approaches for unicompartmental knee arthroplasty are well-accepted for treating knee arthritis because of the smaller implant size, shorter operative time, and tissue-sparing nature of the procedure. With the introduction of computer alignment systems, a well-aligned and balanced total knee arthroplasty (TKA) can be achieved even with smaller surgical exposures. We hypothesi...
متن کاملRobot-assisted implantation improves the precision of component position in minimally invasive TKA.
Minimally invasive and robot-assisted procedures have potential advantages when used for total knee arthroplasty (TKA). The purpose of this cadaveric study was to examine whether robot-assisted minimally invasive procedures improve TKA alignment after modifying the robotic techniques and instruments. Total knee arthroplasties were performed on 10 pairs of fresh cadaveric femora. Ten knees were ...
متن کاملDeviation between navigated and final 3-dimensional implant position in mini-invasive unicompartmental knee arthroplasty
BACKGROUND AND PURPOSE Unicompartmental knee arthroplasty (UKA) is an established method of treating isolated gonartrosis. Modern techniques such as computer-assisted surgery (CAS) and minimally invasive surgery (MIS) are attractive complementary methods to UKA. However, the positioning of the components remains a concern. Thus, we performed a prospective study to assess whether there was devia...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Computer aided surgery : official journal of the International Society for Computer Aided Surgery
دوره 17 1 شماره
صفحات -
تاریخ انتشار 2012