The Charnley versus the Spectron hip prosthesis: clinical evaluation of a randomized, prospective study of 2 different hip implants.
نویسندگان
چکیده
Prospective, randomized studies must be performed when new surgical techniques or implants are evaluated. In this study, a new implant system was compared with the Charnley prosthesis, which over the years has been the most used hip implant in Sweden. Between 1985 and 1989, 410 hips were randomized to treatment with a Charnley or a Spectron total hip arthroplasty: 206 Charnley and 204 Spectron prostheses were implanted. The patients were operated on by a standardized procedure using a contemporary cementing technique. The patients were followed prospectively by an independent observer after 1, 3, 5 to 6, and 10 years. Harris Hip Score and patient satisfaction were recorded in the outcome evaluation. A total of 144 patients with 164 hips were deceased, and 15 patients (8 Charnley and 7 Spectron) have required a revision. Nine hips were revised because of aseptic loosening (5 Charnley stems and 4 Spectron metal-backed cups). The Charnley stem as well as the metal-backed Spectron cup had a higher risk for revision because of aseptic loosening. The Charnley ogee cup and the Spectron stem have performed remarkably well with no revision of these components. Seven Charnley prostheses dislocated, but no dislocation was recorded in the Spectron group. Survivorship calculations with a mean follow-up of 10 years revealed an overall 11-year survivorship of 94.5% +/- 3.4% (Charnley, 93.2% +/- 5.8%; Spectron, 95.9% +/- 3.0%). The clinical outcome did not differ between the 2 systems. The overall results in this old population, using a contemporary surgical technique, illustrate that cemented hip arthroplasty is an excellent treatment alternative for elderly patients.
منابع مشابه
Wear and migration of highly cross-linked and conventional cemented polyethylene cups with cobalt chrome or Oxinium femoral heads: a randomized radiostereometric study of 150 patients.
This randomized study was performed to compare wear and migration of five different cemented total hip joint articulations in 150 patients. The patients received either a Charnley femoral stem with a 22.2 mm head or a Spectron EF femoral stem with a 28 mm head. The Charnley articulated with a γ-sterilized Charnley Ogee acetabular cup. The Spectron EF was used with either EtO-sterilized non-cros...
متن کامل18 years of results with cemented primary hip prostheses in the Norwegian Arthroplasty Register
BACKGROUND AND PURPOSE Few studies have compared the long-term survival of cemented primary total hip arthroplasties (THAs), and several prostheses have been used without adequate knowledge of their endurance. We studied long-term outcome based on data in the Norwegian Arthroplasty Register. PATIENTS AND METHODS The 10 most used prosthesis brands in 62,305 primary Palacos or Simplex cemented ...
متن کاملThe use of probabilistic decision models in technology assessment : the case of total hip replacement.
There is increasing recognition that decision modelling is central to health technology assessment and, in particular, to analyses to support formal decision making regarding the funding of the use of new technologies. In part, the key role of decision analysis stems from the need to handle multiple sources of uncertainty in the available evidence. The use of probabilistic decision analysis is ...
متن کاملA randomized study on migration of the Spectron EF and the Charnley flanged 40 cemented femoral components using radiostereometric analysis at 2 years
BACKGROUND AND PURPOSE We performed a randomized study to determine the migration patterns of the Spectron EF femoral stem and to compare them with those of the Charnley stem, which is regarded by many as the gold standard for comparison of implants due to its extensive documentation. PATIENTS AND METHODS 150 patients with a mean age of 70 years were randomized, single-blinded, to receive eit...
متن کاملEffect of Coating Materials on the Fatigue Behavior of Hip Implants: A Three-dimensional Finite Element Analysis
This study aims to validate, using finite element analysis (FEA), the design concept by comparing the fatigue behavior of hip implant stems coated with composite (carbon/PEEK) and polymeric (PEEK) coating materials corresponding to different human activities: standing up, normal walking and climbing stairs under dynamic loadings to find out which of all these models have a better performance in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of arthroplasty
دوره 14 4 شماره
صفحات -
تاریخ انتشار 1999