Power Quality Indices for Unbalance Characterization in Non‐sinusoidal Condition

نویسندگان

  • Andrei Cziker
  • Anca Miron
  • Mircea Chindris
چکیده

The unbalanced non-sinusoidal operation represents a common steady state of the modern distribution power grids. The unbalance is produced by supplying of unbalanced loads or by different unbalanced faults. According to the existing norms, this operating state is evaluated using the well-known negative and zero unbalance factors that practically keep out the harmonic pollution that coexists with the unbalance. The paper proposes a new way of determining the negative and zero unbalance factors, which takes into consideration the non-sinusoidal operating state, too. At the end of the paper, some study cases are analyzed in order to underline the difference between the existing way to evaluate the unbalance in harmonic polluted systems and the proposed one.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Coordinated Control Scheme for Improving Voltage Quality Using Power Electronics Interfaced DGs

Recently, increasing of non-linear loads in the power distribution network has been increased harmonics in these networks. The harmonics problems get worse and complicated by installation of power factor correction capacitors and filters. But the Distributed Generations (DGs) interface inverters with properly control can help to improve power quality, harmonic compensation and voltage unbalance...

متن کامل

Active Power Conditioners to Mitigate Power Quality Problems in Industrial Facilities

Non-linear loads are commonly present in industrial facilities, service facilities, office build‐ ings, and even in our homes. They are the source of several Power Quality problems such as harmonics, reactive power, flicker and resonance [1-3]. Therefore, it can be observed an in‐ creasing deterioration of the electrical power grid voltage and current waveforms, mainly due to the contamination ...

متن کامل

Contribution Determination for Multiple Unbalanced Sources at the Point of Common Coupling

Three-phase unbalance is an important power quality issue that can cause many negative effects to the power system. Effective mitigation and management of voltage unbalance will benefit from the knowledge of how the unbalanced sources contribute to the voltage asymmetry at the point of evaluation (POE). In this paper, a method is proposed to assess the overall unbalance contribution of the mult...

متن کامل

Time Domain Method to Detect Harmonic Sources in Unbalanced Power Systems

− In recent years the problem of harmonic pollution has become more urgent, because of the development in distribution systems of non linear loads that draw non-sinusoidal currents. This paper presents a time domain method for harmonics sources detection in power systems, which can be usefully applied also in presence of unbalance or asymmetry. Harmonic power flows are calculated in real time a...

متن کامل

A Comparison Between Electrical Circuit and Finite Element Modeling Methods for Performance Analysis of a Three-Phase Induction Motor under Voltage Unbalance

Induction motor is the most popular load in the industry, it is very important to study about the effects of voltage quality on induction motor performance. One of the most important voltage quality problems in power system is voltage unbalance. This paper evaluates and compares two methods including finite element method (FEM) and equivalent electrical circuit simulation for investigation ...