An ultrasensitive protein array based on electrochemical enzyme immunoassay.
نویسندگان
چکیده
An ultrasensitive electrochemical enzyme immunoassay (EEIA) for the detection of proteins on an 8x8 array is described. The assay is based on wired enzyme technology. Briefly, capture antibody was covalently immobilized on a self-assembled 11-mercaptoundecanoic acid (MUA) monolayer coated gold electrode. After incubating with a target protein (antigen), the gold electrode was treated sequentially in biotinylated detection antibody solution and in avidin-horseradish peroxidase conjugate (A-HRP) solution. A cationic redox polymer (electrochemical mediator) overcoating was applied to the gold electrode through layer-by-layer electrostatic self-assembly. The formation of a bilayer brought the HRP in electrical contact with the underlying electrode, making the bilayer an electrocatalyst for the reduction of hydrogen peroxide where the redox polymer acts as an artificial mediator. Consequently, the concentration of protein could be quantified amperometrically. This electrochemical immunoassay combined the specificity of the immunological reaction with the sensitivity of the electrochemical detection. The applicability of the system in protein detection was demonstrated with a snake toxin, beta-bungarotoxin, a neurotoxin from the venom of the snake Bungarus multicinctues. Under optimized experimental conditions, the assay allowed the detection of beta-bungarotoxin in the range of 20 pg/mL to 1.5 ng/mL with a detection limit of 10 pg/mL (20 fg). A higher detection limit of 25 pg/mL was obtained in serum.
منابع مشابه
Electrochemical stripping analysis of nanogold label-induced silver deposition for ultrasensitive multiplexed detection of tumor markers.
A multiplexed electrochemical immunoassay method was developed for simultaneous ultrasensitive measurement of tumor markers based on electrochemical stripping analysis of silver nanoparticles (Ag NPs). The Ag NPs were deposited on a disposable immunosensor array with a reduction reaction catalyzed by nanogold labels. The immunosensor array was prepared by covalently immobilizing capture antibod...
متن کاملUltrasensitive enzyme-free electrochemical immunosensor based on hybridization chain reaction triggered double strand DNA@Au nanoparticle tag.
An ultrasensitive enzyme-free electrochemical immunoassay was developed for detection of the fg/mL level carcinoembryonic antigen (CEA) by using a double strand DNA@Au nanoparticle (dsDNA@AuNP) tag and hexaammineruthenium(III) chloride (RuHex) as the electroactive indicator. The dsDNA@AuNP was synthesized by one-pot hybrid polymerization of dsDNA on initiator DNA modified AuNPs via hybridizatio...
متن کاملAn interference-free and rapid electrochemical lateral-flow immunoassay for one-step ultrasensitive detection with serum.
Point-of-care testing (POCT) of biomarkers in clinical samples is of great importance for rapid and cost-effective diagnosis. However, it is extremely challenging to develop an electrochemical POCT technique retaining both ultrasensitivity and simplicity. We report an interference-free electrochemical lateral-flow immunoassay that enables one-step ultrasensitive detection with serum. The electr...
متن کاملFabrication of an Electrochemical Immunosensor for Determination of Human Chorionic Gonadotropin Based on PtNPs/Cysteamine/AgNPs as an Efficient Interface
An ultrasensitive electrochemical immunosensor for the detection of tumor marker human chorionic gonadotropin (hCG) was developed with a limit of detection as low as 2 pg mL-1 in phosphate buffer. The Platinum nanoparticles (PtNPs) were electrodeposited to modify the gold surface and to increase enlarging the electrochemically active sites, resulting in the facilitation of electron exchange. Cy...
متن کاملDisposable immunosensor array for ultrasensitive detection of tumor markers using glucose oxidase-functionalized silica nanosphere tags.
An ultrasensitive multiplexed electrochemical immunoassay method was developed for the detection of tumor markers by combining a newly designed trace tag and a disposable immunosensor array. The array was prepared by immobilizing capture antibodies on gold nanoparticles which were assembled on carbon nanotubes-chitosan modified screen-printed carbon electrodes. The trace tag was prepared by loa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Frontiers in bioscience : a journal and virtual library
دوره 10 شماره
صفحات -
تاریخ انتشار 2005