Combining a dynamic battery model with high-resolution smart grid data to assess microgrid islanding lifetime
نویسندگان
چکیده
In this paper, we use experimental data collected from an Austin, Texas smart grid test bed with a system-level battery energy storage model to assess the lifetime of batteries in a microgrid operating in islanded mode during a distribution-level outage. We consider a hypothetical microgrid consisting of 21 single-family detached homes and three transformer-level community energy storage (CES) battery units ranging in size from 25 kW h to 75 kW h. To describe the performance of CES batteries, we implement a dynamic behavioral circuit model capable of describing voltage transients and rate-capacity effects. We use one-minute electricity production and consumption data collected from the smart grid test bed in 2012 to assess how the timing of an electric outage affects the islanding lifetime of a residential microgrid. We contrast our results with the average outage duration reported by U.S. electric utilities to quantify how often a residential microgrid could withstand a typical outage. Our results show that increasing the amount of rooftop PV in a residential microgrid does not significantly increase how often it can withstand an average-duration outage. However, combining PV with CES extends the median islanding lifetime by up to 11.6 h during morning outages. Based on our results, 50 kW h CES provides the best tradeoff between the cost of a CES system and its reliability benefit, allowing downstream loads to withstand an average-duration outage approximately 93% of the time. 2014 Elsevier Ltd. All rights reserved.
منابع مشابه
A New Method for Hybrid Energy Storage Capacity Determination in Isolated Micro Grid
In recent years, hybrid energy storage (HES) to increase lifetime and reliability extremely are used in renewable systems and microgrids. In this paper, a new method for determining battery and supercapacitor capacity in an isolated microgrid is presented. Difference between Generation and load power using discrete fourier transform is transferred to the frequency domain and by determining the ...
متن کاملImplementation of Optimal Load Balancing Strategy for Hybrid Energy Management System in DC/AC Microgrid with PV and Battery Storage
The proposed paper presents the DC/AC microgrid modeling using the Energy storage units and photovoltaic (PV) panels. The modal consists of a two stage power conversion. The power is supplied to the both DC and AC loads by this PV solar panels. The suitable way to explore the PV generation model is by using manufacturer datasheet. A bidirectional converter is connected to the battery storage sy...
متن کاملThe FUSE testbed: establishing a microgrid for smart grid security experiments
Reliable and efficient energy supply is based not only on local control but also on remote sensor data and measurements, making communication one of the important components. The increasing threat of possible attacks is the motivation behind the main purpose of the FUSE testbed—an experimental microgrid for smart grid research—to conduct experiments on smart grid security, grid optimization, st...
متن کاملOptimal Economic Operation and Battery Sizing for Microgrid Energy Management Systems Considering Demand Response
Microgrids (MGs) contain a diverse mix of energy resources to provide safe and secure power to the consumers. Batteries are utilized in MGs for further energy security assurance as well as cost minimization. In this paper, an efficient approach is introduced for simultaneous energy management and optimal battery sizing to accomplish economic MG operation. Also, demand response programs are empl...
متن کاملStabilizing Microgrid Frequency by Linear Controller Design to Increase dynamic response of Diesel Generator frequency Control Loop
In this paper, a distributed generation including diesel generators, wind turbines, and microturbines are introduced, and their mathematical model is described using the Taylor expansion method. With the goal of computational complexity eliminating, the reduced order model (ROM) of microgrid components is considered. The results of the studies indicate that the microgrid frequency is unstable...
متن کامل