Arcing Fault Detection in Distribution Lines
نویسنده
چکیده
Partial discharge of an insulator or surge arrester is a symptom of an insulation breakdown or insulation failure. It is very important to know the position of discharge source as soon as possible in order to remove this cause. In order to achieve remote monitoring of the faults due to an insulator and surge arrester on the distribution systems, the most important things need to do is to determine the type of fault. The correlation of voltage and current in an electrical arc is entirely different from that in solid conductors. In this paper, an overview of main fault location techniques and arc modeling principles were given. Preliminary laboratory tests on insulators and surge arresters and field tests on an overhead line were presented. Simulations of faults on a distribution system were carried out for the fault identification and location. These indicated that known signatures are associated with these types of failures which could be used for fault recognition. More importantly, specific configuration of the network at the point of measurement need to be known and taken into account in the analysis in order to provide accurate location of the fault.
منابع مشابه
A Novel Fault Detection and Classification Approach in Transmission Lines Based on Statistical Patterns
Symmetrical nature of mean of electrical signals during normal operating conditions is used in the fault detection task for dependable, robust, and simple fault detector implementation is presented in this work. Every fourth cycle of the instantaneous current signal, the mean is computed and carried into the next cycle to discover nonlinearities in the signal. A fault detection task is complete...
متن کاملArcing Fault Detection and Fault Location on Hv Transmission Lines
In this paper a new numerical algorithm for fault distance calculation and arcing fault recognition, based on one terminal data and derived in the time domain, is presented. The algorithm is derived for the case of most frequent single-phase line to ground fault. The faulted phase voltage is modelled as a serial connection of the fault resistance and the arc voltage. The fault distance and the ...
متن کاملArc Fault Detection Through Model Reference Estimation
In most arc fault circuit breakers, arc detection is accomplished through the signature analysis of remotely sensed branch currents, with high frequency spectral components being indicative of arcing. This paper presents an alternative approach based upon system identification. A model is assumed for the load on the distribution bus. This model is updated continuously by comparing measured volt...
متن کاملNumerical Methods for the Analysis of Power Transformer Tank Deformation and Rupture Due to Internal Arcing Faults
Power transformer rupture and fire resulting from an arcing fault inside the tank usually leads to significant security risks and serious economic loss. In order to reveal the essence of tank deformation or explosion, this paper presents a 3-D numerical computational tool to simulate the structural dynamic behavior due to overpressure inside transformer tank. To illustrate the effectiveness of ...
متن کاملOne Terminal Digital Algorithm for Adaptive Single Pole Auto-Reclosing Based on Zero Sequence Voltage
This paper presents an algorithm for adaptive determination of the dead timeduring transient arcing faults and blocking automatic reclosing during permanent faults onoverhead transmission lines. The discrimination between transient and permanent faults ismade by the zero sequence voltage measured at the relay point. If the fault is recognised asan arcing one, then the third harmonic of the zero...