Comparison of two methods of fibrescope-guided tracheal intubation.

نویسندگان

  • J E Smith
  • A A Mackenzie
  • V C Scott-Knight
چکیده

We have compared intubation time and cardiovascular effects of fibrescope-guided orotracheal intubation aided by the Berman 11 Intubating Airway with those of the tongue traction method of fibreoptic intubation and with conventional Macintosh intubation. We studied 75 patients who received a standard general anaesthetic which included non-depolarizing neuromuscular block; they were allocated randomly to one of the three groups immediately before intubation. The mean time required to effect Berman airway intubation (34.9 s) was similar to that required for tongue traction intubation (35.3 s) and significantly greater than that required for Macintosh intubation (11.7 s). The cardiovascular responses to both types of fibreoptic intubation were significantly greater and more prolonged than those of Macintosh intubation. There were no significant differences between the responses to the two fibreoptic techniques. Haemodynamic effects should be considered when performing fibrescope-guided tracheal intubation under general anaesthesia and, when necessary, appropriate measures should be taken to minimize them.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of hemodynamic changes of Propofol and Thiopental during

Introduction: General anesthesia is the most common technique for performance of various surgical procedures. Thiopental is the most common anesthetic agent for intravenous induction. Since the introduction of propofol as an anesthetic agent, its use has increased progressively and has become the drug of choice for induction of anesthesia in several conditions. The aims of this study were com...

متن کامل

The i-gel Supraglottic Airway as a Conduit for Fibreoptic Tracheal Intubation - A Randomized Comparison with the Single-use Intubating Laryngeal Mask Airway and CTrach Laryngeal Mask in Patients with Predicted Difficult Laryngoscopy.

Fibreoptic intubation through a supraglottic airway is an alternative plan for airway management in difficult or failed laryngoscopy. The aim of this study was to compare three supraglottic airways as conduits in patients with at least one predictor for difficult laryngoscopy. The i-gel was compared with the single-use intubating laryngeal mask airway (sILMA) and CTrach laryngeal mask in 120 ad...

متن کامل

Comparison of the effect of thiopental sodium-midazolam combination on the hemodynamic response between tracheal intubation and laryngeal mask airway insertion: A clinical trial study

Background and Aim: The purpose of this study was to compare the effect of thiopental sodium-midazolam combination on the stress response and hemodynamic changes between tracheal intubation and laryngeal mask airway insertion during airway management. Materials and Methods: In this clinical trial study, 70 patients ASA 1, 2 candidates for elective surgery were randomly divided into two groups o...

متن کامل

Brief report: tracheal intubation using the Bonfils intubation fibrescope or direct laryngoscopy for patients with a simulated difficult airway.

BACKGROUND The Bonfils intubation fibrescope (BIF), a rigid, straight and reusable fibreoptic device, is being used increasingly to facilitate endotracheal intubation after direct laryngoscopy has failed. We tested the hypothesis that, with the BIF compared to direct laryngoscopy, the rate of failed endotracheal intubation could be reduced in patients with a difficult airway, simulated by means...

متن کامل

Cost comparison of re-usable and single-use fibrescopes in a large English teaching hospital.

A number of studies in the U.S.A. and mainland Europe have described the costs of fibreoptic tracheal intubation. However, no such data from the UK appear available. We performed a cost assessment of fibreoptic intubation, using re-usable (various devices from Olympus, Acutronic and Karl Storz) and single-use (Ambu aScope) fibrescopes, at the Queens Medical Centre, Nottingham, U.K., between 1 J...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 66 5  شماره 

صفحات  -

تاریخ انتشار 1991