Commutable calibrator with value assigned by the IFCC reference procedure to harmonize serum lactate dehydrogenase activity results measured by 2 different methods.

نویسندگان

  • Giampaolo Cattozzo
  • Elena Guerra
  • Ferruccio Ceriotti
  • Carlo Franzini
چکیده

BACKGROUND The availability of commutable calibrator materials may ease considerably the task of harmonizing assay results and ensuring their traceability to reference procedures. We sought to verify the commutability of potential calibrator materials and evaluate their effectiveness in harmonizing LDH results by 2 measurement methods. METHODS We measured LDH in 109 serum samples and 31 materials, including frozen serum pools (with either normal or abnormal isoenzyme patterns), commercial stabilized materials, and the ERM-AD453/IFCC reference material. We assayed LDH activity with the IFCC reference procedure and with 2 commercial methods, 1 using the lactate-to-pyruvate (LP) reaction, and the other the pyruvate-to-lactate (PL) reaction. We selected a commutable material, with LDH value assigned by the reference procedure, as a calibrator for recalculating the results for patient sera by both LP and PL, thereby making them traceable to the IFCC reference procedure. RESULTS Original values for patient sera (n = 109) by the 2 commercial methods showed a mean (SD) PL/LP ratio of 1.97 (0.03); this ratio changed to 1.06 (0.02) after recalculation of results. Linear regression of PL vs LP recalibrated values gave y = 1.108x - 9.7. At the clinically important concentration of 250 U/L (upper reference limit), the systematic difference between methods was 6.8%, which met our proposed quality specifications for inaccuracy and total error. CONCLUSIONS By properly selecting the calibrator, the results of serum LDH measurement by 2 different methods may be harmonized and made traceable to the selected highest (reference) metrological level.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Protein standardization V: value transfer. A practical protocol for the assignment of serum protein values from a Reference Material to a Target Material International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) IFCC Scientific Division

We present a practical protocol for the assignment of values to serum proteins in a Target Material using a Reference Material. This protocol is based on the model of Direct Value Transfer between serum matrices and is intended to improve the value assignment of commercial calibrators using the Reference Material CRM 470 (now labeled ERM-DA 470) or similar The exclusive for all languages and co...

متن کامل

Difference in bias approach for commutability assessment: application to frozen pools of human serum measured by 8 direct methods for HDL and LDL cholesterol.

BACKGROUND We used a difference in bias approach to evaluate the commutability of 4 frozen serum pools for 8 direct methods for measurement of HDL and LDL cholesterol (HDLC and LDLC). METHODS Freshly collected nonfrozen sera from 138 diseased and 37 nondiseased patients and 4 frozen pools from the CDC Lipid Standardization Program were measured by direct methods and by the beta-quantification...

متن کامل

A commutable cytomegalovirus calibrator is required to improve the agreement of viral load values between laboratories.

BACKGROUND Viral load testing for cytomegalovirus (CMV) is an important diagnostic tool for the management of transplant recipients and immunocompromised individuals; however, inconsistency among laboratories in quantitative measurements of viral load limits interinstitutional comparisons. These inconsistencies stem from the lack of assays cleared by the US Food and Drug Administration, the abs...

متن کامل

The importance of commutability of reference materials used as calibrators: the example of ceruloplasmin.

BACKGROUND Different methods for ceruloplasmin tend to give different results in external quality assessment schemes. During the production of the certified reference material ERM-DA470k/IFCC discrepant measurement results were also found for ceruloplasmin measured with different methods, and consequently the protein could not be certified in the material. METHODS We performed a commutability...

متن کامل

VARIATIONS BY EPINEPHRINE OF HEPATIC AND SERUM AMINOTRANSFERASES AND LACTATE DEHYDROGENASE IN THE RAT

Incubation of rat hepatocytes with epinephrine inhibited alanine aminotransferase (ALT) (80%) and aspartate aminotransferase (AST) (53%) activities with no effect on lactate dehydrogenase (LDH) activity. Injection of epinephrine caused a progressive increase with time in hepatic LDH activity, being 52% at 24 h. Preinjection with propranolol eliminated the hormone effect and caused further ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 54 8  شماره 

صفحات  -

تاریخ انتشار 2008